Maintenance

ADDING AND CHANGING THE PUMP OIL

WARNING

The operating temperature of the pump is 70° C / 158° F or higher. Wear gloves when servicing the pump or let 

it cool off sufficiently to prevent injuries.

ADDING OIL

1. 

Remove the oil filler cap

2.  Add oil up to the maximum-level mark; use oil according to DIN 51506, lubrication oil group VC. When in 

doubt, consult your dealer.

3. 

Replace the oil filler cap.

4.  After several packing cycles, check the oil level and add as needed.

CHANGING OIL

1.  Remove the oil drain plug and drain the oil.

2.  Replace the drain plug.

3. 

Remove the oil filler cap.

4.  Add the correct oil up to the maximum-level mark.

5. 

Replace the oil filler cap.

6. 

To reset the service interval counters after the oil change: Start machine and while the display shows the 

hours or cycles, press and hold the      button.

NOTE

Collect the oil to have it processed and recycled according to the locally applicable regulations.

SEAL BEAMS AND COUNTER BEAMS

To achieve a quality seal, it is necessary that the seal beam and counter beam are in good condition.

1.  Clean the seal and counter beams daily with a dry cloth.

2. 

Replace the Teflon tape on the seal beam if damaged and replace the sealing wire if kinked.

3.  Replace the silicone rubber seal if it is burned in.

Depending on the type of machine, there are three seal beam versions:

1. 

Single-seal beam (T2).

2.  Stainless steel seal beam.

3.  Aluminum seal beam.

SINGLE-SEAL BEAM

REMOVE THE SEALING WIRE AND TEFLON TAPE AS FOLLOWS:

1.  Grab the seal beam in the middle and pull it straight up and out of the machine.

2.  The beam is held in place by 2 pins; some force may be necessary to loosen the beam.

3. 

Remove the brown Teflon tape that is applied to the seal beam.

4.  Remove the two screws on the underside of the seal beam; this releases the sealing wire.

5. 

Clean the seal beam thoroughly and remove any glue residue off the Teflon tape.

Summary of Contents for VP-NL-0050-LS

Page 1: ...Vacuum Packaging Machine Model VP NL 0050 LS Item 45310 Instruction Manual Revised 02 28 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...7 28 29 30 31 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...entre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro d...

Page 5: ...devices may never be by passed RESIDENTIAL USERS Vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non commercial or reside...

Page 6: ...add oil if necessary Never operate the machine when the oil level is low It is recommended to change the oil at least every 2 months Turning on Machine If so equipped like some mobile and double cham...

Page 7: ...e with a transparent cover will start when the cover is closed Off Turns the machine off When pressing the button once the symbol will start blinking and the pump will stop after about 4 seconds When...

Page 8: ...is turned on the value may be adjusted by pressing the and buttons Resets the original value Saves changes and returns to the Home menu Multi Functional button Performs various functions depending on...

Page 9: ...mber of exceeded operating hours or cycles To reset the service interval counters after the oil change Start machine and while the display shows the hours or cycles press and hold the button to reset...

Page 10: ...ct the next function with the button 8 Press the menu button to save the entered values and to return to the Home menu Turning Program Functions ON OFF The following functions can be turned ON OFF for...

Page 11: ...n the display when the machine is started up In addition the display will indicate how many hours or cycles remain before an oil change is required After passing the service limit the display will ind...

Page 12: ...e oil to have it processed and recycled according to the locally applicable regulations Seal Beams and Counter Beams To achieve a quality seal it is necessary that the seal beam and counter beam are i...

Page 13: ...m 4 Remove the mounting plates on both ends of the seal beam by loosening the screws this releases the sealing wires and or sealing and cutting wires 5 Clean the seal beam thoroughly Notes After remov...

Page 14: ...e screws Notes Check the strip of fiber glass for damage and replace if necessary Check the springs and replace if necessary Using the seal beam without the springs may cause the sealing wires to brea...

Page 15: ...he struts dampers and springs checked by your dealer once every 5 years and have them replaced as necessary Have the gas struts replaced if the lid no longer opens properly Vacuum Hoses and Tubes Chec...

Page 16: ...eplace the silicon rubber seal There is not enough gas in the bag The bag is too small Select a bigger bag The programmed gas level is too low Increase the gas level value The bag is not correctly pos...

Page 17: ...17 Parts Breakdown Model VP NL 0050 LS 45310 Vacuum Pump...

Page 18: ...18 Parts Breakdown Model VP NL 0050 LS 45310 Worktable...

Page 19: ...19 Lid Parts Breakdown Model VP NL 0050 LS 45310...

Page 20: ...20 Parts Breakdown Model VP NL 0050 LS 45310 Seal Bar...

Page 21: ...21 Parts Breakdown Model VP NL 0050 LS 45310 Vacuum Valve...

Page 22: ...22 Parts Breakdown Model VP NL 0050 LS 45310 Switch Box...

Page 23: ...23 Parts Breakdown Model VP NL 0050 LS 45310 Control Panel...

Page 24: ...5310 9 65829 Hexagon Socket Head Cap Screw M8x16 for 45310 33 35889 Hose Clip ABA 44 56mm for 45310 136 35532 Tension Spring 880 STE for 45310 10 AM523 Mounting Bracket Switch Box Pos1 for 45310 104 3...

Page 25: ...42 AM541 Actuator Switch MB for 45310 64 62726 ISO 4762 M4x25 Hexagon Socket Head Cap Screw for 45310 14 AM532 O Ring 45x3mm for 45310 43 35320 Hex Socket Head Cap Screw M4x8 DIN912 A2 for 45310 65 6...

Page 26: ...4 PVC Tube 40x3 L 50 ST ST Line for 45310 27 AM552 Nut M6x18 for 45310 42 35447 Castle Washer M10 for 45310 12 35889 Hose Clip ABA 44 56mm for 45310 28 35916 Capnut High M6 D1587 A2 for 45310 43 35948...

Page 27: ...5 Plastic for 45310 6 35306 Fuse Clamp 2 5 2 ZSI for 45310 16 65713 Wartel M12x1 5 KS for 45310 26 35305 End Fent for 45310 7 27782 Hexagon Flangenut M5 DIN6923 A2 for 45310 17 65714 Moer M12x1 5 KS...

Page 28: ...28 Electrical Schematics Model VP NL 0050 LS 45310...

Page 29: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 30: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 31: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 32: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: