![Omcan VP-NL-0040-M Instruction Manual Download Page 20](http://html1.mh-extra.com/html/omcan/vp-nl-0040-m/vp-nl-0040-m_instruction-manual_4170534020.webp)
20
Troubleshooting
The machine does not seal.
The bag is not correctly positioned
over the sealing beam.
Adjust the bag position.
The sealing wire is broken.
Replace the sealing wire.
The thermal safety of the power
supply was tripped.
Wait until the safety resets, which
can take half an hour. Decrease
the sealing time.
The electrical contacts of the seal
beam have fouled.
Remove the seal beam and clean
the pins and contacts with sand
paper.
The service symbol appears when
turning on the machine, indicating
the remaining production hours or
cycles.
The service interval counters
have reached their maximum
programmed values.
To reset the service interval
counters after the oil change: Start
the machine and while the display
shows the hours or cycles, press
and hold the “X” button.