background image

11

Troubleshooting

ERROR CODES

Fault Code

Causes

Solutions

EE1

Open circuit or short 

circuit of temperature 

probe.

Check if the plug on mainboard is loosened or not, or 

change temperature probe.

EE2

Open circuit or short 

circuit of defrosting probe.

Check if the plug on mainboard is loosened or not, or 

change defrosting probe.

EE3

Open circuit or short 

circuit of overheating 

probe.

Check if the plug on mainboard is loosened or not, or 

change overheating probe.

EE4

Overheating probe starts 

protecting program (58°C 

/ 136.4°F)

Too much dust on condenser, clean the condenser.

Condenser motor stops working, repair or change the 

motor.
The unit is too close to the wall, keep product at least 

50cm from the wall.

Ambient temperature is too high, ensure the ambient 

temperature stays between the specified range.

GENERAL TROUBLESHOOTING

Problem

Causes

Solutions

Strange noise under the bottom 

shelf.

Fan blade broken.

Power off and fix the blade.

Not refrigerating in spite of normal 

operation.

Unit is off.

Power on.

Melting process.

Stop the melting process.

Refrigerant leaking.

Patch the leak and refill refrigerant.

Unit failure.

Call Omcan.

Weak air from air curtain, and 

higher cabinet temperature.

Evaporator blocked by frost.

Increase melting frequency.

Inside fan damaged.

Replace the fan.

Too low set point of temperature 

controller.

Adjust the set point.

Vent blocked by storage.

Remove the storage.

Normal air curtain, but higher 

cabinet temperature.

Insufficient refrigerant.

Refill the refrigerant.

Too high set point of temperature 

controllers.

Adjust the set point for the 

temperature controller.

The wind curtain disturbed by 

strong air flow.

Removing the disturbing factors.

Ambient temperature or humidity 

beyond standards.

Improve the conditions.

Summary of Contents for RS-CN-0468

Page 1: ...Revised 03 01 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcase Model RS CN 0468 Item 47277 Instruction Manual...

Page 2: ...5 16 17 18 19 Table of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Wa...

Page 3: ...T RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED D...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...de un envio Omcan favor inspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no e...

Page 6: ...and this may cause a fire DO NOT USE EXTENSION CORDS Protect cables Never break or damage the cables as this may cause current leakage resulting in a fire No water flushing Never spray down refrigerat...

Page 7: ...can Inc at 1 800 465 0234 to schedule an Omcan authorized service technician to repair the equipment locally Unauthorized maintenance will void the warranty Warranty covers electrical and part failure...

Page 8: ...ion for 12 hours prior to use Plug the refrigerator in a 110V socket exclusively for the unit After the refrigerator is running test the air suction to confirm it is sufficiently cold Then you may put...

Page 9: ...e display will flash for 3 seconds and it will be restored to the factory setting SWITCHING OPERATION 1 ON OFF switch Press it to I the machine start working Press it to O the machine stop working 2 L...

Page 10: ...eep refrigerator cold and closed if power is ever off Only allow a skilled service individual with proper tools to repair damaged power cables Never touch compressor as it can result in injury If supp...

Page 11: ...stays between the specified range GENERAL TROUBLESHOOTING Problem Causes Solutions Strange noise under the bottom shelf Fan blade broken Power off and fix the blade Not refrigerating in spite of norm...

Page 12: ...nting of the unit Improve the venting conditions Heat protection of compressor failure Replace the heat protection Capillary is blocked by ice Replace the drying filter Temperature controller failure...

Page 13: ...13 Model RS CN 0468 47277 Parts Breakdown...

Page 14: ...14 Model RS CN 0468 47277 Parts Breakdown...

Page 15: ...ation Shield Board for 47277 47 AI123 Main Board for 47277 82 AI276 Evaporator for 47277 15 AI300 Fixing Panel of Front Glass Deflector for 47277 48 67652 LED Transformer for 47277 83 AI277 Back Foam...

Page 16: ...16 Model RS CN 0468 47277 Electrical Schematics...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: