Maintenance
CABINET CLEANING
The product should be cleaned once a week with the power supply disconnected. When cleaning please use a
mild cleansing agent. Only use a damp cloth.
Operation
BEFORE USE
•
Plug refrigerator into the 110V exclusive socket.
• After the refrigerator is running, confirm that air suction/filtration is in working order and that it is sufficiently
cold. After checking to make sure the refrigerator is working properly, it may be used.
DIGITAL TEMPERATURE CONTROLLER
FEATURES OF FUNCTION
• Small, integrated digital controller, which is applicable to the compressor of 1 Hp. Located behind the front
grill.
•
Main functions are: Temperature Display/Temperature Control/Manual-Automatic /Light Control/Value
Storing/Self-Testing/Parameter Locking.
FRONT PANEL OPERATION
1. Set temperature: Press button; set temperature will be displayed. Press or button to modify and
store the displayed value. Press button to exit the adjustment and display the cold-room temperature.
2. If no button is pressed within 10 seconds, the cold-room temperature will be displayed.
3.
Lighting: Press button to activate light in refrigerator; press again to turn off. Manual start/stop defrost:
Press button and hold for 6 seconds to either defrost or to stop defrost.
4. Refrigeration LED: During refrigeration, the LED is on. When the cold room temperature is constant, the
LED is off. During delay start, the LED flashes.
5.
Defrost LED: During defrosting, the LED is on. When it stops defrosting, the LED is off. During the delay of
defrost, the LED flashed.