Parameter Function
Set Range
E1
Lower set point limit.
-45°C ~ Set temp.
E2
Higher set point limit.
Set temp. ~ 45°C.
E3
Temp. hysteresis.
1 - 10°C.
E4
Comp. start delay time.
0 - 10 mins.
E5
Offset on room temp.
-5 - 5°C.
E6
Offset on evap. temp.
-5 - 5°C.
F1
Max. defrost duration.
1 - 60 min.
F2
Defrost interval time.
0 - 24 Hr.
F3
Defrost termination temp.
0 - 20°C.
F4
Display during defrost.
0 = normal display.
1 = last value before defrost.
CLEANING
For health standards and good quality of beverages or foods, clean interiors of the unit as often as possible.
CAUTION: Do not clean the unit by means of a water jet or pressurized washer.
1. Before carrying out cleaning, turn the unit off and remove the power plug.
2. Do not use abrasive powders that might damage the interior parts of the showcase.
3. Use neutral soap and warm water to wash the interiors. Rinse carefully with water in order to remove any
soap residues.
4. To maintain a high standard of working performance, leave the unit turned on during the night and day to
avoid deposits.
CAUTION: Do not use any damaging solvents (petrol, alcohol, etc.) for cleaning the unit. The unit may
get damaged. Do not use and sharp objects for cleaning. The unit may be cleaned with a damp towel
but should never directly come in contact with water. After cleaning the unit, make sure all parts are
dried completely.
INSTRUCTIONS FOR DISPOSAL
When replacing your old unit with a new one, comply with the following information: Old units are not to be
•
Press SET again to select sequential from the 10 parameters: E1, E2, E3, E4, E4, E5, F1, F2, F3, F4.
•
Press the
or
button, the different parameters will be displayed and can be modified and stored.
•
If no more buttons are pressed within 10 seconds, the cold room temperature will be displayed.