![Omcan RE-CN-0036-C Instruction Manual Download Page 8](http://html1.mh-extra.com/html/omcan/re-cn-0036-c/re-cn-0036-c_instruction-manual_4063553008.webp)
8
Installation
plugging it in.
•
Make sure that the unit drops down to desired temperature before loading the unit with product.
•
Maker sure that there is proper ventilation around the unit in the area where it will operate.
•
Make sure all accessories are installed (i.e. poly pans, drawers, casters) before plugging the unit in.
•
Please read through the Operation / Owners Manual in its entirety.
UNCRATING
TOOLS REQUIRED
•
Adjustable Wrench.
•
Phillips Screwdriver.
•
Level.
The following procedure is recommended for uncrating the unit:
•
Remove the outer packaging, (cardboard and bubbles or Styrofoam corners and clear plastic). Inspect for
concealed damage. Again, immediately file a claim with the freight carrier if there is damage.
• Move your unit as close to the final location as possible before removing the wooden skid.
CABINET LOCATION GUIDELINES
INSTALL THE UNIT ON STRONG AND LEVELED SURFACES
•
Unit may make unpleasant noises if surface is uneven.
•
Unit may malfunction if surface is uneven.
INSTALL THE UNIT IN AN INDOOR, WELL-VENTILATED AREA
• Unit performs more efficiently in a well-ventilated area.
•
For best performance, please maintain clearance of 3” on the back of the unit.
• Outdoor use may cause decreased efficiency and damage to the unit.
AVOID INSTALLATION IN A HIGH HUMIDITY AND/OR DUSTY AREA
• Humidity could cause unit to rust and decrease efficiency of the unit.
•
Dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least once a month
with a brush or clean cloth.
•
Malfunction due to dirty condenser will void warranty.
SELECT A LOCATION AWAY FROM HEAT AND MOISTURE-GENERATING EQUIPMENT
• High ambient temperature will cause the compressor to overwork, leading to higher energy bills and
gradual breakdown of the unit.
•
Malfunction due to high ambient temperature will void warranty
ELECTRIC INSTALLATION & SAFETY
INFORMATION
•
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or its service agent.
Summary of Contents for RE-CN-0036-C
Page 15: ...15 Parts Breakdown Model RE CN 0036 C 50070 ...
Page 17: ...17 Parts Breakdown Model RE CN 0052 C 50071 ...
Page 19: ...19 Parts Breakdown Model RE CN 0072 C 50072 ...
Page 21: ...21 Electrical Schematics Model RE CN 0036 C 50070 ...
Page 22: ...22 Electrical Schematics Model RE CN 0052 C 50071 ...
Page 23: ...23 Model RE CN 0072 C 50072 Electrical Schematics ...