12
Maintenance
• Metal ring, drawplate and filter: unscrew the metal ring with the appropriate wrench (Fig.30 A) being careful
not to let any pieces fall, since the metal ring is moved from its place, the product and parts still weigh a few
kilos and can easily slip from your hands, causing damage both to people or to the pieces themselves.
• Archimedean screw: after disassembling the ring nut, the drawplate and the filter, the Archimedean screw
can easily be taken off the machine by pushing its spiral from the internal end.
COVER AND POOL CLEANING
Eliminate the dough residue and be sure to thoroughly clean the most remote-access pieces: connections of
the Archimedean screw (Fig.31 B) and mixer (Fig.31 A) movements, extrusion sleeve, pool internal parts and
cover grid. Use some warm water in order to eliminate the residual product and then rinse; dry the surfaces
with the help of blotting paper and disinfectant, with a soft cloth dipped in odourless disinfectant.
WARNING: Never use non-nutritional, abrasive or corrosive chemicals to clean. Also never use coarse
or abrasive objects such as steel wool, abrasive sponges and so on.
To clean the internal and external parts of the machine:
•
Remove power supply plug from power mains socket.
•
Clean coated surfaces with soft cloth and disinfect with alcohol.
•
For the inside parts of the machine, take off the bigger back panel (Fig.33 A) and carry out the cleaning
of the machine, bearing in mind the grease and dust, that are sometimes present; when finished, replace
panel.
CLEANING OF MIXER, ARCHIMEDEAN SCREW, METAL RING, FILTER, DRAWPLATE
AND KNIVES
WARNING: The alternative knife must not be taken apart: remove product left overs with a soft brush.
Eliminate the dough residue and wash the pieces with water; you may use a soft brush or a plastic pallet knife.
These elements can be thoroughly washed in a dishwasher. Rinse and dry the mixer, the Archimedean screw,
the metal ring and the knife and reassemble them on the machine. The drawplate and filter must be kept in a
container placed in water for the entire period in which they are not being used. For reasons of hygiene, please
change the water every day.
WARNING: Clean the surface below the machine daily, if necessary, temporarily move the machine
from its usual working position.
MAINTENANCE AND ADJUSTMENT
WARNING: Remember that all maintenance operations are dangerous if you do not first disconnect the
power supply plug from the power mains.
The machine parts requiring maintenance are the following: the Archimedean screw reducer, the upright push-
bearing support, the movable mixer support, the sliding chains and belts. Disassemble the bigger back panel
(Fig.33 A) upright.
Summary of Contents for PM-IT-0080
Page 15: ...15 Figure Drawings...
Page 16: ...16 Figure Drawings...
Page 17: ...17 Figure Drawings...
Page 18: ...18 Figure Drawings...
Page 19: ...19 Figure Drawings...
Page 20: ...20 Figure Drawings...
Page 21: ...21 Figure Drawings...
Page 22: ...22 Parts Breakdown Model PM IT 0080 13286...
Page 23: ...23 Parts Breakdown Model PM IT 0080 13286...
Page 24: ...24 Parts Breakdown Model PM IT 0080 13286...
Page 26: ...26 Electrical Schematics Model PM IT 0080 13286...
Page 27: ...27 Electrical Schematics Model PM IT 0080 13286...
Page 28: ...28 Electrical Schematics Model PM IT 0080 13286...
Page 29: ...29 Electrical Schematics Model PM IT 0080 13286...
Page 30: ...30 Electrical Schematics Model PM IT 0080 13286...