Maintenance
CAUTION! Blade can cut body parts! Never place hands in the cutting area between the gauge plate
and the blade if the thickness adjustment lever (5) is not in the safety position (Fig. M). During blade
cleaning and sharpening, be extremely careful to keep hands as far away from the unprotected area as
possible. Use of protective gloves is recommended.
USE OF THE SHARPENER
Follow the instructions below for sharpening:
1.
Position the slice thickness adjuster knob (5) (Fig. M) in the safety position (in position 0).
2.
Pull the meat table (8) all the way back toward the operator.
3. Start removing the meat table, unscrewing the meat table clamp (14) in the anticlockwise direction until the
meat table has been completely removed (Fig. N).
4.
Assemble the sharpener in position, screwing the meat table clamp (14) (Fig. O) in the clockwise position.
5.
Set the slice thickness adjustment knob (5) in position 20 and move the sharpener toward the gauge plate
(6).
6.
Activate the blade by pressing the start button.
7. Sharpen the blade, moving the sharpening wheel against the blade for 10-15 seconds, using the meat table
clamp (14) and applying slight pressure (Fig. P).
CAUTION! Excessive pressure may affect sharpening.
8. Press the finishing wheel button (1) for 2-3 seconds and pull the meat table (8) all the way back toward the
operator.
9. Move the sharpener away from the gauge plate (6), position the slice thickness adjuster knob (5) in the
safety position (in position 0) (Fig. M).
10.
Start removing the sharpener, unscrewing the meat table clamp (14) in the anticlockwise direction until the
sharpener has been completely removed (Fig. Q).
11.
Start assembling the meat table (9), screwing the meat table clamp (14) (Fig. R) in the clockwise position.
SERVICE
No replacement parts are supplied in the package. All repair and replacement activities (such as replacement
or repair of the blade, belt, electrical components, structural parts, etc.) must be carried out solely by persons
authorised by Omcan. If a repair is required, it is advisable to return the machine to Omcan or to an Authorised
Service Centre. For information about services centres, contact: [email protected]
WARNING! The blade must be replaced when the distance between the edge of the blade itself and the
internal edge of the protection exceeds 5mm.
Summary of Contents for MS-IN-0250H-R
Page 12: ...12 Figure Drawings ...
Page 13: ...13 Figure Drawings ...
Page 14: ...14 Figure Drawings ...
Page 15: ...15 Parts Breakdown Model MS IN 0250H R 47111 Model MS IN 0250H BK 47113 ...
Page 16: ...16 Parts Breakdown Model MS IN 0250H R 47111 Model MS IN 0250H BK 47113 ...
Page 17: ...17 Parts Breakdown Model MS IN 0250H R 47111 Model MS IN 0250H BK 47113 ...
Page 19: ...19 Electrical Schematics Model MS IN 0250H R 47111 Model MS IN 0250H BK 47113 ...