12
Maintenance
the mixing blades are mounted correctly. To facilitate this operation there are numbers stamped on the mixing
blades and on the pins on the inside of the bowl. The number on the blade must correspond to the number on
the pin. Once the mixing blades have been mounted close the grille.
AUTOMATIC USE
AUTOMATIC MIXER
1. Press the drive push-button “1”: the blades will start turning and the indicator light “4” will go on.
2.
Press the reverse drive push-button “3”: the indicator light “5” will start flashing. After 30 seconds, the
machine will automatically reverse drive. Every 30 seconds it will invert blade rotation. After 2 minutes (4
cycles) the machine will automatically stop
AUTOMATIC SWITCH-OFF
1. Press the drive push-button “1”: the blades will start turning and the indicator light “4” will go on.
2. Press the drive push-button “1” again. After 1 minute, the machine will automatically stop. The same
sequence can be run in reverse drive.
CHECKS CARRIED OUT ON OUR PREMISES
The purchased appliance has undergone several factory tests. These tests are:
Before setting to work:
• Check operative tension in the appliance which must correspond to the customer’s requirements.
•
Check that there are all the warning plates and notices and the ID plate gives all the correct information
and serial number.
• Check bolt tightening torque.
•
Check that the appliance corresponds and conforms with the regulations in force and with what is given in
this manual.
With the appliance running:
• Check efficiency of all protections and safety features. When the grille is raised the appliance must
automatically stop.
•
General functional check.
•
Repeated tests to make sure the appliance works correctly for its use.
CHECKS AND TESTS TO BE CARRIED OUT WHEN INSTALLING
To make sure the appliance has not been damaged when delivered or when being installed, carry out the
following tests;
Before setting to work:
•
Check that the power supply tension corresponds to the value given on the ID plate.
•
Check that there are all the warning and ID plates and that they are not damaged.
•
Check that the power supply cable is not damaged and is intact.
•
Check that the safety features such as the magnetic sensors are intact and not damaged.