10
Installation
The ice machine should be installed in a proper location meeting the following conditions:
• Indoor, not more than 2,000 meters above sea level.
• Ambient temperature cannot exceed 24°C.
• Power supply: the rated voltage indicated on the machine nameplate ±6%.
• Water source: potable water, with water pressure from 1.3 bar to 5.5 bar; water temperature: 5-35°C.
•
The ice machine should be kept away from heat sources, and should be strictly forbidden to use at
extremely high temperature or low temperature environment, and should avoid direct sunlight.
• There should be sufficient ventilation space around the ice machine and keep good ventilation; the distance
from the ice maker to the wall should be no less than 30 cm for the front, 15cm for the sides, and 20 cm for
the rear.
• The ice machine must be placed on a floor sufficient to support its weight.
•
Socket for the ice maker must be reliably grounded and with leakage protection.
• Proper floor drainage must be provided near the installation location of the ice machine.
INSTALLATION STEPS
1.
Check if the ice machine is in good condition and the accessories are complete; check the machine model
and the machine nameplate.
2.
Clean the ice bin and the food area inside with a sponge soaked in warm water and soda. Then wash and
dry it with potable water.
3.
Place the ice machine in the operation area; ensure that the machine is placed on a leveled floor. So as to
ensure the water flows evenly on the evaporator.
4. The compressor chamber is located at the back. The compressor and condenser are installed in it. For air
cooled unit, it requires good ventilation. Therefore, the front and rear of the ice maker must have ventilation
space of more than 20-30 cm.
5.
The bottom of the ice machine is equipped with adjustable legs for level adjustment and floor cleaning.
6.
Connect the machine’s inlet water filter and water pipe referring to the schematic diagram of installation; if
the installation site is already equipped with a drinking water system, the water filter may not be installed.
Note: the filter flow direction should be correctly installed as per the direction marker on the filter
head cover or the filter body.
Note: this machine is equipped with an inlet water filter. The filter will keep impurities from the
water used as the machine is running. Generally, it needs to be replaced every month to every 3
months.
7. Connect the machine to the water supply using the 3/4” inlet pipe supplied with the machine. It is
recommended to install a water valve (not supplied with this machine) on the water supply line.
8. Connect the drain pipe to the drain connection. In order to meet a good draining, it is recommended that
the drain pipe should have a difference of level more than 3cm per meter; and confirm that the drain pipe is
not blocked. It is recommended that the drain pipe be connected to an open drainage port.
9.
Any joint in the drain pipe must not be higher than the machine drainage port; any joint in the drain pipe
cannot be higher than the previous joint.
10. Confirm the power requirements stated in the machine nameplate; ensure that the power supply meets the
requirements.
11.
A circuit breaker or switch with leakage protector and reliably grounding is required.
12.
Turn off the switch on the power line and connect the machine to the power source.
Summary of Contents for IC-CN-0089S
Page 17: ...17 Parts Breakdown Model IC CN 0089S 47773 ...
Page 19: ...19 Parts Breakdown Model IC CN 0129S 47483 ...
Page 21: ...21 Model IC CN 0219S 47484 Parts Breakdown ...
Page 23: ...23 Model IC CN 0289S 47774 Parts Breakdown ...
Page 25: ...25 Model IC CN 0329 47485 Parts Breakdown ...
Page 27: ...27 Model IC CN 0529 46452 Parts Breakdown ...
Page 29: ...29 Model IC CN 0089S 47773 Model IC CN 0289S 47774 Electrical Schematics ...