![Omcan IC-CN-0012 Instruction Manual Download Page 18](http://html1.mh-extra.com/html/omcan/ic-cn-0012/ic-cn-0012_instruction-manual_3950612018.webp)
18
Troubleshooting
The ice cubes have
shape deformities
Filter
Water filtration element
needs to be changed.
Replace the filter.
Water trough
Water trough level is too
low.
Adjust the water floater.
Cubes are partially
formed—are white at the
bottom
The room temperature
The room temperature
is out the stated range,
the water pump stops
automatically.
Make the temperature
return within the stated
range.
Water trough
Water trough level is too
low.
Adjust the water floater.
OTHER PROBLEMS
Problem
Check part or point
Possible Cause
Probable Correction
The body is electrified
Ground line
The ground line isn't in
the socket.
Please use the socket
meeting the standard.
Lines
The lines are not
insulated.
Adjust, reconnect /
replace lines
Electric component
The electric component is
not insulated.
Replace this electric
component.
Scales occur frequently
inside the machine
The water quality
The rigidity of the water
quality is too high.
Use a water-soften
apparatus installed in
front of the water inlet.
Loud noise during
operation
Spring of the internal
compressor
The spring of the internal
compressor drops.
Replace the compressor.
Water pump
The noise of the water
pump
Replace the water pump.
Pipeline system
Pipeline system resonate Clear pipeline system
Feet
The feet are not leveled
Level and lock the feet.
Fan motor
The fan motor is loose,
the clearance of the rotor
is bigger, the fan blade
turns back
Relocate the fan motor /
replace
Water is leaking out of the
unit
The operation
Some water drops to the
floor when you open the
door to take out ice from
ice storage bin.
Normal condensation on
the door or some water
from the ice. Take care
when you take out ice.
Water supply connection
Water supply connection
is leaking.
Tighten the fitting.
Drainage tray on top of
the compressor
Water full probe is out of
function
Replace with a new one.