9
Troubleshooting
Problem
Possible Cause
Solution
The indicator is not on.
The compressor does not start.
The plug isn’t connected to the
socket really
Replug it.
No power
Connect the socket with power.
The indicator is on, but the
compressor doesn’t work and
buzzes only.
The power voltage is <98V.
Put a power-regulater more than
1000W power together.
The compressor stops a minute
after start, and restart after a few
minutes, and so repeatedly.
The power voltage is >132V.
The compressor works normally,
but the temperature in the cabinet
lowers too slowly.
The door is opened too frequently
Reduce open times.
The food in the cabinet is too
much, and placed improperly
Place foods properly keep place
between them for ventilation of
cold air.
The frost film is too thick.
Take out foods and defrost.
The surface of the condenser is
too dirty.
Stop and clean the condenser.
The door seals badly.
Adjust the door seal.
The noise is too loud.
The freezer is placed unstably.
Place it stably.
The fixing of the freezer is loose.
Tighten the fixing.
There’s contact between pipes.
Separate them.
Maintenance
DEFROSTING
• Defrost for better freezing efficiency when the frost film in the cabinet is 4-5mm thick.
• When defrosting, turn off the power, take out the frozen foods, open the door for warming and melting. Use
soft cloth to absorb water and clean it up.
• Do not use sharp metal tools such as steel brush to clean the frost film when defrosting so as to avoid
evaporator damage.
Summary of Contents for FR-CN-0155
Page 10: ...10 Model FR CN 0155 45294 Parts Breakdown...
Page 11: ...11 Parts Breakdown Model FR CN 0198 45295...
Page 12: ...12 Model FR CN 0230 45296 Parts Breakdown...
Page 13: ...13 Parts Breakdown Model FR CN 0412 45297...
Page 16: ...16 Electrical Schematics Model FR CN 0155 45294 Model FR CN 0198 45295...
Page 17: ...17 Electrical Schematics Model FR CN 0230 45296...
Page 18: ...18 Electrical Schematics Model FR CN 0412 45297...