Omcan CE-CN-WOK NG Instruction Manual Download Page 6

6

Technical Specifications

Model

CE-CN-WOK NG

Burner BTU

95,000

Gas Type

Natural Gas

Number of Burners

1

Pre-Heat Time

5 minutes

Cooking Area 

Dimensions

13” / 330mm diameter

Gas Inlet Size

3/4” / 19mm

Weight

70.5 lbs. / 32 kgs.

Packaging Weight

88.2 lbs. / 40 kgs.

Dimensions

17.5” x 25.1” x 35.6” / 444 x 638 x 905mm

Packaging Dimensions

17.9” x 22.6” x 22.8” / 455 x 575 x 580mm

Conversion Kit Included

No

Item Number

47351

Installation

UNPACKING

This Wok range was inspected before leaving the factory. The carrier assumes full responsibility for the safe 

delivery upon acceptance of the shipment. Check for possible shipping damage immediately after receipt.

If the Wok is found to be damaged, complete the following steps:

1. 

Carrier must be notified within 5 business days of receipt.

2. 

Carrier’s local terminal must be notified immediately upon discovery (note time, date, and who was spoken 

to), and follow up and confirm with written or electronic communication.

3.  All original packing materials must be kept for inspection purposes.

4. 

The Wok range can’t have been moved, installed, or modified.

Remove all packing material and protective plastic from the surfaces of the unit. Before installing, verify that 

the type of gas (natural or propane) and the clearance dimensions agree with the specifications on the rating 

plate which is located at the right side of the wok range.

LOCATION

The installation location must be kept free and clear of combustibles. Do not obstruct the flow of combustion 

and ventilation air. DO NOT install the Wok range adjacent to open burners or fryers. Sufficient air should be 

allowed to enter the room to compensate for the amount of air removed by any ventilating system and for 

combustion of the gas burners. Do not obstruct the air flow into and around the appliance. Do not obstruct 

the flow of flue gases through and above the Wok range top grate. Position the Wok range in its final location. 

Check that there are sufficient clearances to service the Wok range and to make the required gas supply 

Summary of Contents for CE-CN-WOK NG

Page 1: ...Gas Wok Range Model CE CN WOK NG Item 47351 Instruction Manual Revised 12 09 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...10 10 11 12 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Regis...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...rse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor a...

Page 5: ...onent failure or other damages resulting from installation in non commercial or residential applications The right is reserved to deny shipment for residential usage if this occurs you will be notifie...

Page 6: ...th written or electronic communication 3 All original packing materials must be kept for inspection purposes 4 The Wok range can t have been moved installed or modified Remove all packing material and...

Page 7: ...esistive to natural gas This range uses NG56 connections for gas nozzles MANUAL SHUT OFF VALVE This installer supplied valve must be in the gas service line ahead of the appliance regulator in the gas...

Page 8: ...e appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as ap...

Page 9: ...e failure device will shut the gas off If you notice the flame was extinguished please turn the flame control valve to OFF position and re ignite the pilot flame A 5 minutes complete shut off period s...

Page 10: ...impossible to remove Ensure your wok range is checked by a qualified technician once a year for efficient operation of the appliance CONTACT THE APPLIANCE SUPPLIER OR A LOCAL SERVICE COMPANY TO PERFOR...

Page 11: ...equirements Adjust nozzle diameter Not enough air to ignite Increase damper opening degree Gas spikes and floats Turn down valve flow THE PROBLEMS MENTIONED ABOVE ARE FOR REFERENCE ONLY IF ANY FAULT O...

Page 12: ...12 Parts Breakdown Model CE CN WOK NG 47351...

Page 13: ...AI578 Support Beam for 47351 11 AI586 Duck Mouth Burner for 47351 20 AI571 Side Plate Left and Right for 47351 4 AI579 Input Pipe Mount Pad for 47351 12 AI587 Union for 47351 21 AI572 Tray Guide for...

Page 14: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: