• Prior to connecting the regulator, check the incoming line pressure, as these regulators can only withstand
a maximum pressure of 1/2 psi (14” WC). If the line pressure is beyond this limit, a step down regulator will
be required.
• The arrow shown on the bottom of the regulator body shows the gas flow direction, it should point
downstream to the appliance. The red air vent cap on the top is part of the regulator and should not be
removed.
• Any adjustments to the regulator should be made only by qualified service personnel with the proper
equipment.
INSTALLATION INSTRUCTIONS
• Installation of all equipment should be performed by qualified, certified, and authorized personnel who are
familiar and experienced with local installation codes.
• Before installation, please read instructions completely and carefully.
• Do not remove permanently affixed labels, warnings, or plates from the product.
• Please observe all local and national codes and ordinances.
• Installation must conform with local codes, or in the absence of local codes, the National Fuel Gas Code,
ANS1 Z223.1 (latest edition). In Canada, installation should conform to installation codes for gas burning
appliances and equipment standard CAN/CGA-B149.1 or the propane installation code, CAN/CGA-B149.2,
as applicable.
• Electrical wiring to the appliance must be electrically grounded in accordance with local codes or in the
absence of local codes with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.2, as applicable.
• A manual gas shut-off valve must be installed in the gas supply line ahead of the appliance and gas
pressure regulator for safety and ease in servicing.
• The gas pressure regulator supplied must be installed on the appliance prior to connecting the equipment
to the gas line. Failure to install a regulator could be potentially hazardous and will void the appliance
warranty.
• The appliance and its individual shut off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45kpa).
• The appliance must be isolated from gas supply piping system, by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 psi (3.45kpa).
OPERATING INSTRUCTIONS
• Operation of this equipment must be performed by qualified or authorized personnel who have read and
are familiar with the functions of the equipment.