background image

14

Instructions for Field Conversion

INSTRUCTION FOR NORMAL OPERATING SEQUENCE:

Pilot Burner Operation:

The units are equipped with standing pilots, and should be lit immediately after the gas is turned on.

• 

Turn off main valve to unit and wait 5 minutes to clear gas.

• 

Turn off all knobs and pilot valves.

• 

Turn on main valve and light all pilots.

•  The pilot burner must be lit at the end of the tube. Hold an ignition source (6” fire lighter). Through the 

opening in the front panel at the pilot tube. When the flame is established remove the ignition source.

Burner Operation:

 To ignite burners, turn burner valve knob to “High” position. Each burner is controlled by 

an individual high-low, on-off valve. An infinite number of grilling temperatures may be obtained by turning the 

burner valve knob to any position between high and low.

Derating at altitudes above 2000 ft (610 m):

 Ratings of gas utilization equipment are based on sea level 

operation and shall not be changed for operation at elevations up to 2000 ft (600m). For operation at elevations 

above 2000 ft (600m), equipment ratings shall be reduced at the rate of four (4) percent for each 1000 ft 

(300m) above sea level before selecting appropriately sized equipment.

Parts Breakdown

Model CE-CN-1219-G 

37524

Item 

No.

Description

Position

Item 

No.

Description

Position

Item 

No.

Description

Position

76278

Griddle Plate Assembly for TH-RGT-48

1

76285

Gas Valve for TH-RGT-48

8

76292

Burner for TH-RGT-48

15

76279

Drip Tray Support Rack for TH-RGT-48

2

76286

Gas Inlet Pipe for TH-RGT-48

9

76293

Screw for TH-RGT-48

16

76280

Nut for TH-RGT-48

3

76287

NG/LPG Conversion Valve for TH-

RGT-48

10

76294

Gas Inlet Pipe Protect Plate for 

TH-RGT-48

17

76281

Drip Tray Assembly for TH-RGT-48

4

76288

Bottom Plate for Control Box for TH-

RGT-48

11

76295

Rear Plate for TH-RGT-48

18

76282

Drip Tray Leakage Pipe for TH-RGT-48

5

76289

Nozzle for Gas Valve for TH-RGT-48

12

76296

Pilot for TH-RGT-48

19

76283

Front Panel for TH-RGT-48

6

76290

Foot for TH-RGT-48

13

76284

Knob for TH-RGT-48

7

76291

Body Shell for TH-RGT-48

14

Summary of Contents for CE-CN-1219-G

Page 1: ...Gas Counter Top Griddles Model CE CN 1219 G Item 37524 Instruction Manual Revised 12 05 2016 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...16 18 19 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Instructions for Field Conversion Parts Breakdown...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el...

Page 5: ...ou smell gas follow the instructions provided by the gas supplier Do not touch any electrical switch do not try to light the burner do not use a telephone within close proximity Never attempt to move...

Page 6: ...off the gas shut off valve Allow the appliance to vent for five minutes before attempting to re light INSTALLATION TO BE DONE BY LICENSED GAS PROFESSIONALS ONLY SET UP 1 Remove all packing material an...

Page 7: ...grates and into the drip tray to reduce flare ups 3 Check the drip tray frequently and add water as necessary 4 To ignite the burners press the gas control knob to high position 5 Allow the equipment...

Page 8: ...down the equipment Pilot Flame Regulation The pilot flame on the equipment has been factory adjusted When adjustment is necessary adjust the pilot flames as small as possible but high enough to light...

Page 9: ...A manual shut off valve should be installed upstream from the manifold within 4 ft 1 2m of the equipment and in a position where it can be reached in the event of an emergency Check entire gas piping...

Page 10: ...and reinstall in griddle 7 Wipe down exterior of griddle cabinet with a clean cloth and non abrasive cleanser Rinse thoroughly with water and a clean cloth Dry with a soft clean cloth Troubleshooting...

Page 11: ...justment Contact qualified technician for adjustment Damaged temperature control burner or other internal component Contact Authorized Omcan Service Agency for repairs REFERENCE Item Number Model Numb...

Page 12: ...an cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing equipment WARNING This conversion kit shall be installed...

Page 13: ...ot in the support bracket Secure by replacing the M5 nut 7 To operate with LP gas the regulator must be changed to operate at 10 WC or use a LP regulator 8 Prior to connecting the regulator check the...

Page 14: ...peration and shall not be changed for operation at elevations up to 2000 ft 600m For operation at elevations above 2000 ft 600m equipment ratings shall be reduced at the rate of four 4 percent for eac...

Page 15: ...15 Parts Breakdown Model CE CN 1219 G 37524...

Page 16: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 17: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: