18
Maintenance
Troubleshooting
the shoulder supports.
• Using a clean cloth moistened with drinking water (but not dripping), wipe all the other surfaces except the
control panel (this must not get wet) but including the parts of the base below the belts, after putting them
in the raised position; finally dry all the surfaces thoroughly with dry cloths.
Do not use metal objects so as not to damage the parts. Do not use water jets/sprays.
Ensure that all parts of the machine are dry before using it; otherwise accumulations and incrustations could
form in some points and could be difficult to remove as time passes.
Fault and/or anomaly
Possible causes
Remedies
The machine will not go on.
No power.
Check that the plug is plugged
in properly, the main switch is on
I (ON) and the electrical protec
-
tion devices in the room have not
tripped; reset as appropriate.
Fuses and/or thermal circuit
breaker tripped.
Change the fuses and/or reset the
device that has tripped.
The machine will not start.
The emergency button has been
pressed.
Rearm it.
An accident-prevention guard has
not been lowered completely.
Lower it completely.
The microswitch associated with
one of the guards has failed.
Get it replaced.
Summary of Contents for 49115
Page 19: ...19 Parts Breakdown Model BE IT 710 CSS 49115...
Page 21: ...21 Parts Breakdown Model BE IT 710 FSS 49116 Base Assembly...
Page 22: ...22 Parts Breakdown Model BE IT 710 FSS 49116 Head Assembly...
Page 24: ...24 Electrical Schematics Model BE IT 710 CSS 49115...
Page 25: ...25 Electrical Schematics Model BE IT 710 FSS 49116...