Maintenance
The wire is now ready to use
If the two wire fastening hooks are not parallel with the work top, align.
The adjustments must only be made with the machine disconnected from the electricity mains.
Do not perform any operations without having received specific authorisation and adequate training on
the operating procedures as well as being informed about the possible dangers.
MAINTENANCE AND CLEANING
PRELIMINARY INSTRUCTIONS
Only qualified, specially trained and authorised personnel should carry out maintenance, cleaning and repair
jobs. Before carrying out any operation, the following precautions must be taken:
• Switch off the power on the machine panel via the power disconnecting device.
At the end of each operation:
• Reset and properly secure all the fixed and/or interlocking guards.
Summary of Contents for 45412
Page 18: ...18 Electrical Schematics Model GR IT 1000 C 45412 Main Disconnector...
Page 19: ...19 Electrical Schematics Model GR IT 1000 C 45412 Auxiliary Power Supply...
Page 20: ...20 Electrical Schematics Model GR IT 1000 C 45412 Cutting Rope Motor...
Page 21: ...21 Electrical Schematics Model GR IT 1000 C 45412 Forward Contactor...
Page 22: ...22 Electrical Schematics Model GR IT 1000 C 45412 Commands...
Page 23: ...23 Electrical Schematics Model GR IT 1000 C 45412 Commands...
Page 24: ...24 Electrical Schematics Model GR IT 1000 C 45412 Machine Safety Relays...
Page 25: ...25 Electrical Schematics Model GR IT 1000 C 45412 Machine Safety Devices...
Page 26: ...26 Electrical Schematics Model GR IT 1000 C 45412 Machine Contemporary Relay...
Page 27: ...27 Electrical Schematics Model GR IT 1000 C 45412 Push Buttons...