Installation

carry, store and handle the unit in a vertical position and follow the instructions found on the packaging.

2. 

If the unit was placed in a non-vertical position during the transportation, keep the unit in a vertical position 

for approximately 24 hours before using the unit and turning it on, to allow the oil to flow back into the 

compressor.

UNPACKING

1. 

Remove the wooden baseboard and plastic covering.

2.  Make sure that the unit has not been damaged.

3.  Remove plastic film from all the stainless-steel panels, if applicable.

IMPORTANT: The packaging should be kept away from children as it is potentially dangerous. Dispose 

of the packaging according to the regulation from the local authorities.

POSITION

1. 

Never clean the unit with pressurized water jets.

2. 

Place the unit on a flat and stable surface.

3. 

Install the unit in a location where it can be overseen by trained personnel.

4. 

For good ventilation, keep 20 cm (7 inches) between the unit and walls or other objects. Increase the 

distance if the objects surrounding are heating sources. When the unit is in place, press the brake on the 

wheels to keep it from moving.

5.  Fix the shelves on the unit.

ELECTRICAL CONNECTION

Before inserting the plug into the electrical socket, carefully read the following precautions:

1. 

Make sure that the unit is correctly connected to a properly grounded outlet, in compliance with current 

safety standards.

2.  Make sure that the voltage is in accordance with what is indicated on the rating label.

3.  The current voltage available should be enough for the maximum energy required by the unit.

4.  If necessary, use multiple outlets, which are all properly grounded, in compliance with current safety 

standards.

5.  If in doubt, please consult qualified technicians.

THE REFRIGERATED SHOWCASE MUST BE CONNECTED TO AN ELECTRICAL SOCKET WITH A 

GROUND.

Operation

Before using, the unit should be completely cleaned as it comes into contact with food.

1.  Make sure that the main switch is in the (I) position, then plug in the unit.

2.  Before starting the unit, ensure the sliding doors are properly closed.

3.  Turn the main switch to the (I) position, the condensing unit will automatically start.

Summary of Contents for 44639

Page 1: ...sed 08 20 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Countertop Refrigerated Showcases Models RS CN 0140 D 0190 D 0240 D Items 44639 44640 46806 Instruction Manual ...

Page 2: ...le of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Model RS CN 0140 D Model RS CN 0190 D Model RS CN 0240 D ...

Page 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Page 4: ...áquina y ésta usando ropa apropiada y autorizada Cualquier modificación a la máquina anúla la garantía y puede causar daños a las personas usando la máquina mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio Omcan favor inspeccionar daños externos Si no hay daños evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos ...

Page 5: ...cu ft 240 L 7 1 cu ft Power 425 W 451 W 461 W Current 2 64A 2 8A 2 86A Refrigerant R134a Number of Shelves 2 Electrical 110V 60Hz 1 Interior Dimensions 15 8 x 35 5 x 14 5 400 x 902 x 368mm 15 8 x 47 3 x 14 5 400 x 1200 x 368mm 15 8 x 59 x 14 5 400 x 1499 x 368mm Dimensions 21 3 x 35 5 x 31 540 x 902 x 787mm 21 3 x 47 3 x 31 540 x 1200 x 787mm 21 3 x 59 x 31 540 x 1499 x 787mm Packaging Dimensions ...

Page 6: ... Increase the distance if the objects surrounding are heating sources When the unit is in place press the brake on the wheels to keep it from moving 5 Fix the shelves on the unit ELECTRICAL CONNECTION Before inserting the plug into the electrical socket carefully read the following precautions 1 Make sure that the unit is correctly connected to a properly grounded outlet in compliance with current...

Page 7: ...set the temperature controller frequently TEMPERATURE CONTROLLER OPERATION Number Function Normal Operation Start Up ON OFF Flash 1 Compressor On Off Call On 2 Fan On Off Call On 3 Defrost On Off Call On 4 Auxiliary Outbut AUX Output active Output not active On 5 Clock RTC RTC available enabled tEN 1 and at least one time band has been set RTC not available or not enabled tEN 0 or no time band set...

Page 8: ...s cycle 2 1 second displays sets the set point For 1 second RESET current EZY set Pressed together 2 and 3 activate parameter reset procedure More than 3 seconds accesses the parameter setting menu password 22 Mutes the audible alarm buzzer 3 More than 3 seconds activates deactivates the defrost Pressed together with 1 activates deactivates the continuous cycle For 1 second displays firmware versi...

Page 9: ... S with 1 2 probes X Y C c3 Minimum compressor on time C 0 100 min 0 S with 1 2 probes X Y C c4 Compressor on time with duty setting C 0 100 min 0 S with 1 2 probes X Y C cc Continuous cycle duration C 0 15 h 4 S with 1 2 probes X Y C c6 Temperature alarm bypass after continuous cycle C 0 15 h 2 S with 1 2 probes X Y C d0 Type of defrost C 0 4 0 S with 1 2 probes X Y C dl Interval between defrosts...

Page 10: ...atic d6 0 cht Not Active ON Dirty condenser pre alarm Automatic Easy Easy Compact A4 10 Easy Split A4 13 CHt Active ON Dirty condenser alarm Manual Easy Easy Compact A4 10 Easy Split A4 13 EtC Not Active ON Clock alarm By setting the time If bands are active SrC Easy Split only Not Active ON Maintenance request signal Manual set HMr 1 HMP HMd HMr CLEANING For health standards and good quality of b...

Page 11: ...Ensure that refrigeration tubing is not damaged prior to disposal Please discard the unit according to the regulations of local law Troubleshooting Problems Possible Reasons Solutions Remarks No power input power direction lamp does not light Broken fuse Replace As for authorized service department to check and repair Poor connection of plug and socket Repair or replace the socket Failure in input...

Page 12: ...r starts stops frequently The winding of the compressor is short circuit Check with a multi meter replace the compressor Poor contact of the socket Repair or replace The fan of the evaporator does not work The fan motor is damaged Replace WARNING If the machine has any problems or has been damaged do not try to repair or replace it by yourself Please contact OMCAN technical service at 1 888 465 02...

Page 13: ...13 Parts Breakdown Model RS CN 0140 D 44639 Model RS CN 0190 D 44640 Model RS CN 0240 D 46806 ...

Page 14: ...008 Condenser Fan for CT540AF 12 AA028 Body for CT540AF 21 66967 Thermostat for CT540AF 4 AA009 Condenser for CT540AF 13 AA029 Shelf for CT540AF 22 66968 Switch for CT540AF 5 AA025 Evaporator for CT540AF 14 AA030 Metal Shelf 1 for CT540AF 23 AA003 Control Panel for CT540AF 6 AA011 Evaporator Fan for CT540AF 15 AA031 Metal Shelf 2 for CT540AF 24 AA004 Panel Fixing Board for CT540AF 7 AA012 Adjustab...

Page 15: ...15 Electrical Schematics Model RS CN 0140 D 44639 Model RS CN 0190 D 44640 Model RS CN 0240 D 46806 ...

Page 16: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 17: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 18: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 19: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Page 20: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 5000 produ...

Reviews: