10
Operation
Maintenance
the causes of the alarm have been resolved. The alarm codes are shown in the table below:
Alarm
Code
Buzzer and
Alarm Relay LED
Alarm Description
Reset
Enable Alarm Parameters
involved
Easy
Easy
Compact
Easy
Split
E0
Active
ON
Probe 1 error=control.
Automatic
-
E1
Not Active
ON
Probe 2 error=defrost.
Automatic
d0= 0 / 1 / 4, F0=1
E2
Not Active
ON
Probe 3 error=condenser/
product.
Automatic
Easy, Easy Compact [A4=10/11]
Easy Split [A4=13/14]
-
IA
Active
ON
External alarm.
Automatic
[A4=1] [+A7]
-
dOr
Active
ON
Open door alarm.
Automatic
Easy, Easy Compact [A4=7/8]
[+A7]
Easy Split [A4=7/8/10/11] [+A7]
-
LO
Active
ON
Low temperature alarm.
Automatic
[AL] [Ad]
HI
Active
ON
High temperture alarm.
Automatic
[AH] [Ad]
EE
Not Active
ON
Unit parameter error.
Not Possible
-
EF
Not Active
ON
Operating parameter error.
Manual
-
Ed
Not Active
ON
Defrost ended by timeout.
On first defrost
ended correctly
[dP] [dt] [d4] [A8]
dF
Not Active
OFF
Defrost running.
Automatic
[d6=0]
cht
Not Active
ON
Dirty condenser pre-alarm.
Automatic
Easy, Easy Compact [A4=10]
Easy Split [A4=13]
-
CHt
Active
ON
Dirty condenser alarm.
Manual
Easy, Easy Compact [A4=10]
Easy Split [A4=13]
-
EtC
Not Active
ON
Clock alarm.
By setting the
time
If bands are active
-
SrC (Easy
Split only)
Not Active
ON
Maintenance request signal.
Manual
set HMr=1
[HMP] [HMd] [HMr]
-
-
CLEANING
For health standards and good quality of beverages or foods, clean interiors of the unit as often as possible.
CAUTION: Do not clean the unit by means of a water jet or pressurized washer.
1. Before carrying out cleaning, turn the unit off and remove the power plug.
2. Do not use abrasive powders that might damage the interior parts of the showcase.
3.
Use neutral soap and warm water to wash the interiors. Rinse carefully with water to remove any soap
residues.
4. To maintain a high standard of working performance, leave the unit turned on during the night and day to
avoid deposits.
CAUTION: Do not use any damaging solvents (petrol, alcohol, etc.) for cleaning the unit. The unit may
get damaged. Do not use and sharp objects for cleaning. The unit may be cleaned with a damp towel