background image

6

Installation

CONVERSION

These instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should 

be done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on 

natural gas. Orifices necessary for Propane (L.P.) are provided in a bag of the manual.

Technical Specifications

Model

CE-CN-0212-S

CE-CN-0424-S

CE-CN-0636-S

Dimensions

12” x 30.3” x 18.9” 

305 x 770 x 480mm

24” x 30.3” x 18.9” 

610 x 770 x 480mm

36” x 30.3” x 18.9” 

915 x 770 x 480mm

Number of Burners

2

4

6

BTU/PER NAT/LP

30, 000

Total BTU/Hr

60, 000

120, 000

180, 000

W.C. IN

6/10

Item Number

44198

44199

44200

Note: Depth direction includes the regulator’s size.

Safety and Warranty

Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not 

improper use.

Please see www.omcan.com/warranty.html for complete info.

WARNING:

The packaging components are classified as normal solid urban waste and can therefore be disposed of 

without difficulty. 

In any case, for suitable recycling, we suggest disposing of the products separately (differentiated 

waste) according to the current norms.

DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Summary of Contents for 44198

Page 1: ...Revised 08 11 2017 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Gas Step Up Hot Plates Models CE CN 0212 S 0424 S 0636 S Items 44198 44199 44200 Instruction Manual...

Page 2: ...2 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Parts Breakdown Warranty Registration Model CE CN 0212 S Model...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...o entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m...

Page 5: ...5 kPa WARNING A factory authorized agent should handle all maintenance and repair Before doing any maintenance or repair contact your authorized service representative SAFETY PRECAUTIONS DANGER Warns...

Page 6: ...770 x 480mm Number of Burners 2 4 6 BTU PER NAT LP 30 000 Total BTU Hr 60 000 120 000 180 000 W C IN 6 10 Item Number 44198 44199 44200 Note Depth direction includes the regulator s size Safety and W...

Page 7: ...7 Installation 1 Shut off the main isolation gas valve and follow the lock out tag out procedure 2 Remove the Tray and Trivets 3 Remove the screws and remove all the cast burners...

Page 8: ...n 4 Remove the Orifice and Replace it Use a 1 2 spanner See the list of Orifice numbers for the appropriate gas type 5 Converting the Gas Regulator a Remove the converter cover from the regulator Use...

Page 9: ...te open the pilot valve more If the pilot flame appears larger than necessary turn it down and reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliab...

Page 10: ...152 mm 6 rear 152 mm 4 floor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 floor 102 mm Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind t...

Page 11: ...An unexpected flare could cause severe injury Turn off the unit let it cool and use potholders and or gloves to reposition or remove The space between the legs at the bottom admits combustion air DO...

Page 12: ...to 20 minutes Then either brush with a wire brush or clean gas ports with a sharp pointed metal instrument to insure open ports CAUTION Clean the regulator at least once a month Make sure the vent ope...

Page 13: ...13 Parts Breakdown Model CE CN 0212 S 44198 Model CE CN 0424 S 44199 Model CE CN 0636 S 44200...

Page 14: ...3 73108 Back Pipe of Pilot Assembly for TR HPSU424M 08 9 63535 Valve Connection for TR HPSU424M 08 15 72410 Foot for TR HPSU424M 08 4 63533 Orifice Connection Rear for TR HPSU424M 08 10 73113 Pilot V...

Page 15: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: