background image

5

Technical Specifications

Installation

Model

# of Burners

Temperature Range

Dimensions (mm)

Item #

TH-RB-1

1

50~300°C

455×532×620

37525

TH-RB-2A

2

50~300°C

455×1064×620

37529

These kinds of gas stoves can be operated by LPG or Natural gas. You may replace the nozzles. But please 

contact Omcan for details of diameter of nozzles. The nozzles are included with the stove or can be ordered 

from manufacturer. The slightest difference in diameter would influence the performance of the burners.

INSTALLATION TO BE DONE BY LICENSED PROFESSIONALS ONLY.

SET UP

1.  Remove all packing material and tape, as well as any protective plastic from the equipment.

2.  Place the equipment in the desired position and height.

3.  Install the four (4) legs onto the equipment.

4.  Clean and dry the equipment thoroughly before using.

INSTALLATION

The installation of this equipment must conform with local codes, or with the National Gas Code, ANSIZ223.1/

NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.

•  The equipment and its individual shutoff valve must be disconnected from the gas supply piping system 

during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

•  The equipment must be isolated from the gas supply piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply piping system at test pressures equal to or less then ½ 

psi (3.5 kPa).

CLEARANCE AND POSITIONING AROUND EQUIPMENT

•  This equipment must be installed adjacent to non-combustible surfaces only with a minimum spacing of 6” 

from all sides. This equipment must be a distance of 6” from other equipment. The equipment must have 

the 4” legs installed and be placed on a non-combustible surface.

AIR SUPPLY AND VENTILATION

•  The area in front and around the equipment must be kept clear to avoid any obstruction of the flow of 

combustion and ventilation air.

•  Adequate clearance must be maintained at all times in front of and at the sides of the equipment for 

servicing and proper ventilation.

Summary of Contents for 37525

Page 1: ...s Stock Pot Burners Item 37525 37529 Instruction Manual Version 2 1 800 465 0234 www omcan com 3115 Pepper Mill Court Mississauga ON L5L 4X5 4450 Witmer Industrial Estates Unit 4 Niagara Falls NY 1430...

Page 2: ...15 17 Table of Contents Section General Information Safety Warranty Technical Specifications Installation Operation Maintenance Instructions for Field Conversion between LP NG Parts Breakdown Warranty...

Page 3: ...note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours so we may initiate a claim with the carrier A detailed report on the extent of the damage caused to the m...

Page 4: ...packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty In any case for suitable recycling we suggest disposing of the products separately...

Page 5: ...Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 as applicable The equipment and its individual shutoff valve must be disconnected from the gas supply piping system during an...

Page 6: ...ight all pilots 4 The pilot burner must be lit at the end of the tube Hold an ignition source through the pilot light hole in the front panel at the pilot tube When the flame ignites remove ignition s...

Page 7: ...e adjustable feet so the equipment is level 2 Check the drip tray frequently and add water as necessary 3 To ignite the burner press and turn the gas control knob to high position 4 Allow the equipmen...

Page 8: ...ool completely before cleaning 2 Using a wire brush scrape the grill grate s to remove any food residue 3 To clean equipment use either a damp cloth sponge with soapy water or a metal scraper 4 Dry gr...

Page 9: ...uthorized service agent In case of troubleshooting ensure the correct orifice sizes of the spuds have been provided Natural Gas Orifice is 31 Liquid Propane Gas Orifice is 52 Orifice size is marked on...

Page 10: ...over the orifice and then locating the M5 stud through the slot in the support bracket Secure by replacing the M5 nut 7 To operate with LP gas the regulator must be changed to operate at 10 WC To do...

Page 11: ...he screws holding the front panel and remove 2 The pilot burner valve is positioned to the right of the control valve a small adjustment screw is located on the front face of the valve body This can b...

Page 12: ...12 Parts Breakdown Model TH RB 1 37525...

Page 13: ...Sides 2 Pilot Igniter 11 Gas Pilot Valve 20 Top Grates 3 Pilot Supporter 12 Adjustable Feet Support 21 Gas Valve 4 Body Back 13 Lower Body Panel 22 Join Part 5 Feet 14 Drip Pan 23 Connection Pipe Shor...

Page 14: ...14 Parts Breakdown Model TH RB 2A 37529...

Page 15: ...ter 22 Front Panel 3 Nozzle Join Part B 13 Pilot Supporter 23 Gas Pipe Holder 4 Join Part 14 M16 x 1 25 Nut with Dia 10 24 Body Sides Support 5 Connection Pipe Long 15 Drip Pan 25 Adjustable Regulator...

Page 16: ...16...

Page 17: ...html Thank you for choosing Omcan Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer...

Page 18: ......

Page 19: ......

Page 20: ...cts Omcan continues to help our customers remain competitive With associates in North America Europe Asia and South America our global footprint continues to expand as we hold to the principle that cl...

Reviews: