3.3.3
Standard lever type positioner Installation Steps
1. Assemble the positioner with the bracket made in previous step by fastening the bolts.
Fig. 3-3: Linear (Standard Lever Type)
2. Attach the positioner with the bracket to the actuator yoke
–
DO NOT TIGHTEN THE BRACKET COMPLETELY.
3. Connect connection bar to the actuator clamp. The hole gap on the feedback lever is 6.5mm so
the connection bar’s outer diameter should be less than 6mm.