3)  Phase Contrast Kits 

 

Model 

Phase Contrast Objective

 

Condenser  Annular Ring Plates 

Centering   

Telescope 

 

A1PHB1 

Plan achromatic 10X with 
built-in phase plate 
 
Plan achromatic 20X with 
built-in phase plate 
 
Plan achromatic 40X with 
built-in phase plate, spring 
 
Plan achromatic 100X with 
built-in phase plate, spring, 
oil 
 

NA 1.25 

five positions: 
10 for 10X phase contrast 
objective 
20 for 20X phase contrast 
objective 
40 for 40X phase contrast 
objective 
100 for 100X phase contrast 
objective 
B for bright field observation, 
with iris diaphragm 
 

focusing   

adjustable

 

 

A1PHB3 

Achromatic 10X with built-in 
phase plate 
 
Achromatic 20X with built-in 
phase plate 
 
Achromatic 40X with built-in 
phase plate, spring 
 
Achromatic 100X with built-in 
phase plate, spring, oil 

five positions: 
10 for 10X phase contrast 
objective 
20 for 20X phase contrast 
objective 
40 for 40X phase contrast 
objective 
100 for 100X phase contrast 
objective 
B for bright field observation, 
with iris diaphragm 
 

 

A1PHC1 

Plan achromatic 10X with 
phase plate 
 
Plan achromatic 40X with 
phase plate 

three positions: 
10 for 10X phase contrast 
objective 
40 for 40X phase contrast 
objective 
middle position for brightfield 
observation 

 

A1PHD 

Achromatic 10X with built-in 
phase plate 
 
Achromatic 40X with built-in 
phase plate, spring 
 
Achromatic 100X with built-in 
phase plate, spring, oil 

10 for 10X phase contrast 
objective 
40 for 40X phase contrast 
objective 
100 for 100x phase contrast 
objective 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for M834 Series

Page 1: ...User Manual Trinocular Compound Microscope Model M834 Series MicroscopeNet com...

Page 2: ...1 Component Illustration 3 2 Installation 4 3 Operation 7 4 Specifications 10 5 Optional Parts 11 6 Troubleshooting Guide 13 7 Darkfield Condenser Installation and Operation Instructions 15 8 Phase C...

Page 3: ...l electrical connectors power cord should be inserted into an electrical surge suppressor to prevent damage due to voltage fluctuations 6 Important the lamp lamphouse and adjacent parts will become ve...

Page 4: ...ng an excessive amount of solvents as this may cause problems with optical coatings or cemented optics or the flowing solvent may pick up grease making cleaning more difficult Oil immersion objectives...

Page 5: ...11 Microscope Base 19 Condenser Holder 4 Slide Holder 12 Eyepiece 20 X Y Stage Moving Knobs 5 Condenser Lock Thumb Screw 13 Diopter Adjusting Ring 21 Light Collector 6 Condenser Focus Knob 14 Eyepiec...

Page 6: ...iece tubes 2 Insert the eyepieces into the eyepiece tubes 2 4 Installation of the objectives 1 Adjust the coarse focus knob until the mechanical stage is at its lowest position 2 Turn the caps counter...

Page 7: ...ight housing 3 Take the eyepieces off and check if the view head is securely locked by the set screw Put the microscope down on its back gently 4 Open the cover on the bottom of the base by pull the k...

Page 8: ...oto tube and then connect the camera to a computer via USB2 0 cable See Fig 6 3 The manual for the camera is on a CD or mini CD Refer to the manual to install the driver and software on to the compute...

Page 9: ...il the specimen is close to the objective 2 Turn the coarse focus knob until the specimen is in focus 3 Use the fine focus knob to obtain a sharp image 4 To get a good focused image you may need to co...

Page 10: ...sting condenser 1 Turn the condenser focus knob to raise or lower the condenser 2 The condenser is raised when using high magnification objectives and lowered when using low magnification objectives N...

Page 11: ...microscope into focus by following the procedures in 3 3 2 Install the camera by following the procedures in 2 8 3 Open image observing software to examine more details see camera s manual 4 If the im...

Page 12: ...Coaxial coarse and fine focusing knobs on both sides w stage upward stopper Minimum fine focusing adjustment at 0 002mm range 30mm Mechanical Stage Large double layer mechanical stage Dimension 5 1 2...

Page 13: ...S Windows 32 64 bit Mac OS Included A1510 1280 x 1024 1 3MP A1520C 1600 x 1200 2 0MP A1530X 2048 x 1536 3 0MP A1550X 2592 x 1944 5 0MP A1590 3488 x 2616 9 0MP MS Windows 32 64 bit 2 Darkfield Condense...

Page 14: ...Achromatic 20X with built in phase plate Achromatic 40X with built in phase plate spring Achromatic 100X with built in phase plate spring oil five positions 10 for 10X phase contrast objective 20 for...

Page 15: ...17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down specimen at the bottom Turn slide over so the cover glass faces up Imm...

Page 16: ...e condenser is not in the right position Lower or raise the condenser slightly to the position that the specimen is the brightest A191BOIL only Make sure the oil contact the bottom of the slide and th...

Page 17: ...e condenser up or down slightly to get the best darkfield viewing Note The dry darkfield condenser is used with the dry objectives only The dry darkfield condenser works with the 4X 10X 40X objectives...

Page 18: ...objectives a Take off all the objectives from the nosepiece b Install the phase contrast objectives onto the nosepiece following the steps in 2 4 2 Mounting the phase contrast condenser annular ring d...

Page 19: ...on focusing etc following the instructions in this manual Note The phase contrast condenser will be working as a conventional Abbe condenser if the annular ring disk being put at B position 8 2 Phase...

Page 20: ...he telescope The bright ring and dark ring should be coincided with each other as shown in Fig 21 d e If the ring images are not clear turn the top of telescope until both ring images are in focus f I...

Page 21: ...is hard to find put a normal white print paper on the stage and under the objective then you will see the dark ring as shown in Fig 24 a h If the bright ring is still obscure as in Fig 24 b raise or l...

Reviews: