RACKON: RACK & PINION PART TURN PNEUMATIC ACTUATOR
RK10 - RK480
2.4 Operating temperature
Standard working temperature range from –20°C (-4°F) to 80°C (176°F).
Actuators for Low or High temperature applications are available, please contact us.
Supplementary protection (e.g. screens, sheds, or integral painting) are strictly recommended for high humidity and low temperature
application.
2.5 Operating drive rotation
Part turn actuator rotation angle is nominally 90° with a ± 5° adjusting stroke: closing setting from -5° to +5° and opening setting from
85° to 95°.
2.6 Cycle time
Cycle time depends on different operational and installation factors such as supply pressure, flow capacity, pipe size connection,
solenoid valve performance, valve torque and characteristics, ambient temperature condition.
Double
Acting
0°- 90°
cycle time
(ms)
90°- 0°
cycle time
(ms)
RK10
23
21
RK20
73
47
RK40
131
110
RK60
160
120
RK80
189
130
RK120
137
125
RK160
183
177
RK240
304
288
RK300
383
354
RK480
522
455
Ambient temperature
18÷25°C (64,4÷77°F)
Supply pressure
compressed air; 5,5 bar (80 psi) for double acting and 6 bar (87psi) for spring return
Operating drive rotation
90° in both directions
Load
free
Spring Return
0°- 90°
cycle time
(ms)
90°- 0°
cycle time
(ms)
RK20
79
60
RK40
155
170
RK60
188
178
RK80
221
187
RK120
220
207
RK160
273
236
RK240
330
342
RK300
559
509
RK480
697
772
Actuator opening, closing and open/close cycle times
Above timetable refers to a standard actuator working cycle at the following tests conditions:
DA actuators operate with solenoid valves 5/2 ISO 1-2, while SR actuators operate with solenoid valves 3/2. Time tested by Electronic
Timer device.
Note
: different working conditions such as air pressure, piping connection, filters, or solenoid valves, could change operations timing.