5
1.2.2.
Protection Circuits
There are several protection circuits used in the amplifier. They are activated when one or more
parameters exceed defined values or some unwanted condition
occurs.
•
VSWR too high
•
Anode current too high
•
Anode voltage error
•
Screen current too high
•
Screen voltage error
•
Grid current too high
•
Grid voltage error
•
Heating voltage error
•
Mistuning of PA
•
Temperature too high
•
Soft start for fuse protection
•
“switch-on blocking “ at opened amplifier
1.2.3.
Features
The manufacturer implemented some of the company’s newest development results with most
wanted operating and safety features into this new model:
•
High level of protection
•
Memory for faults and warnings, easy maintenance
•
Automatic set-up anode current (BIAS) – no need to adjust manually after changing the
tube
•
Three programmable working modes of the centrifugal blower ( turbine ) + axial blower
•
Full QSK
•
Many operational parameters to display
•
Easy transport due to detachable HV transformer
•
The smallest and lightest 4000 W Power Amplifier on the market