Table 2  HAR flexible cord

Approval organizations and cordage harmonization marking methods

Approval organization

Printed or embossed 

harmonization marking (May be 

located on jacket or insulation of 

internal wiring)

Alternative marking utilizing 

black-red-yellow thread (Length 

of color section in mm)

Black

Red

Yellow

Comite Electrotechnique Belge

(CEBEC)

CEBEC 

<HAR>

10

30

10

Verband Deutscher Elektrotechniker

(VDE) e.V. Prüfstelle

<VDE> 

<HAR>

30

10

10

Union Technique de I´Electricite´

(UTE)

USE 

<HAR>

30

10

30

Instituto Italiano del Marchio di

Qualita´ (IMQ)

IEMMEQU 

<HAR>

10

30

50

British Approvals Service for Electric

Cables (BASEC)

BASEC 

<HAR>

10

10

30

N.V. KEMA

KEMA-KEUR 

<HAR>

10

30

30

SEMKO AB Svenska Elektriska

Materielkontrollanstalter

SEMKO 

<HAR>

10

10

50

Österreichischer Verband für

Elektrotechnik (ÖVE)

<ÖVE> 

<HAR>

30

10

50

Danmarks Elektriske Materialkontroll

(DEMKO)

<DEMKO> 

<HAR>

30

10

30

National Standards Authority of Ireland 

(NSAI)

<NSAI> 

<HAR>

30

30

50

Norges Elektriske Materiellkontroll

(NEMKO)

NEMKO 

<HAR>

10

10

70

Asociacion Electrotecnica Y

Electronica Espanola (AEE)

<UNED> 

<HAR>

30

10

70

Hellenic Organization for

Standardization (ELOT)

ELOT 

<HAR>

30

30

70

Instituto Portages da Qualidade

(IPQ)

np   

<HAR>

10

10

90

Schweizerischer Elektro

Technischer Verein (SEV)

SEV 

<HAR>

10

30

90

Elektriska Inspektoratet

SETI 

<HAR>

10

30

90

Underwriters Laboratories Inc. (UL) 

SV, SVT, SJ or SJT, 3 X 18AWG

Canadian Standards Association (CSA) 

SV, SVT, SJ or SJT, 3 X 18AWG

Summary of Contents for STM7-CB

Page 1: ... to familiarize yourself fully with the use of this microscope we recommend that you study this manual thoroughly before operating the microscope Retain this instruction manual in an easily accessible place near the work desk for future reference Control box for manual Control box for motorized Optical Microscope Accessory STM7 CB STM7 CBA ...

Page 2: ... if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance c...

Page 3: ...Contents Introduction 1 Safety precautions 1 1 Specifications 4 Proper selection of the power supply cord 6 ...

Page 4: ......

Page 5: ...product is used in a manner not specified by this manual the safety of the user may be imperiled In addition the product may also be damaged Always use the equipment according to this instruction manual The following symbols are used in this instruction manual CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Indicates a potenti...

Page 6: ...units This device is designed for use in Class A industrial environment for IEC61326 1 International Standard concerning EMC Using it in a domestic environment may cause radio interference This device complies with the emission and immunity requirements described in IEC61326 series CAUTION Electric safety Do not insert any tools or metal fragments in the air vents of the device Doing so could caus...

Page 7: ...alling it vertically could cause it to fail from excessive heat 2 After the DIP switch is set be sure to attach the seal at the original position 3 Set the DIP switch when the main switch is OFF and then set the main switch to ON If the DIP switch is set when the main switch is ON the setting is not reflected 4 Do not touch the connector pins of modules with your hands directly The modules may be ...

Page 8: ...l box is connected to the autofocus unit STM7 AF OFF The control box is not connected to the autofocus unit STM7 AF HALF ON The counter data of X Y and Z axis is displayed in 1 2 value of the actual movement distance OFF The counter data of X Y and Z axes is displayed normally EPI SEL ON The reflected light illumination can be controlled OFF The reflected light illuminator cannot be controlled DIA...

Page 9: ... Humidity 65 10 Operation guarantee Temperature 10 C to 35 C Humidity 30 to 85 Standby condition Temperature 0 C to 40 C Humidity 20 to 85 Storage condition Temperature 10 C to 60 C Humidity 10 to 90 Safety standards Indoor use Altitude Max 2 000 meters Ambient temperature 5 to 40 C 41 to 104 F Maximum relative humidity 80 for temperatures up to 31 C 88 F without condensation In case of over 31 C ...

Page 10: ...ly the power supply cord which is approved by one of the agencies mentioned in Table 1 please use replacements approved by any other equivalent and authorized agencies in your country Country Agency Certification mark Country Agency Certification mark Argentina IRAM Italy IMQ Australia SAA Japan JET JQA Austria ÖVE Netherlands KEMA Belgium CEBEC Norway NEMKO Canada CSA Spain AEE Denmark DEMKO Swed...

Page 11: ...ctric Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 Österreichischer Verband für Elektrotechnik ÖVE ÖVE HAR 30 10 50 Danmarks Elektriske Materialkontroll DEMKO DEMKO HAR 30 10 30 National Standards Authority of Ireland NSAI NSAI HAR 30 30 50 Norges Elektriske Materiellkontroll NEMKO NEMKO HAR 10 10 70 Asocia...

Page 12: ...us Tower 446 Bongeunsa ro Gangnam gu Seoul 06153 Korea Distributed by Manufactured by 48 Woerd Avenue Waltham MA 02453 U S A Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com ...