background image

EN 21

En

Dry the Case

After washing with pure water, use a lint-free soft cloth without any salt on it to wipe off any waterdrop 
and dry the Case completely at a well ventilated location in the shade.

CAUTION:

Do not use hot air from a hair drier or the like for drying and do not expose the Case to direct sunlight, as this 
may accelerate deterioration and deformation of the Case and deterioration of the O-ring, leading to leakage 
of water.
When wiping the Case, take care not to cause scratches.

PT-E06_EN.Book  Page 21  Thursday, February 26, 2009  5:04 PM

Summary of Contents for PT E06

Page 1: ...http www olympus com VN212101 Printed in China PT E06 取扱説明書 デジタルカメラ 用防水プロテクター Instruction Manual Underwater Case for digital camera En PT E06 Instruction Manual PT E06_JP COVER fm 1 ページ 2009年2月26日 木曜日 午後5時14分 ...

Page 2: ...d contents due to water entering the camera will not be compensated z OLYMPUS IMAGING CORP shall not pay any compensation for accidents injuries or material damage at the time of use For safe use This instruction manual uses various pictographs for correct use of the product and to prevent danger to the user and other person as well as property damage These pictographs and their meanings are shown...

Page 3: ...direct sunlight in an automobile etc Locations close to fire A water depth in excess of 40 m Locations subject to vibrations Locations with high temperature and humidity or with extreme temperature changes Locations with volatile substances 3 Opening and closing at locations with much sand dust or dirt may impair the waterproof characteristic and cause water leakage This should be avoided 4 This p...

Page 4: ...make it impossible to open the Case a For safe use of the digital camera in this product please read the Instruction Manual for the digital camera carefully b When sealing this product take sufficient care that no foreign matter gets caught at the O ring and the contact surfaces c The camera s built in flash cannot be used when the Case is combined with an external Olympus flash Also the camera s ...

Page 5: ...l camera to the camera table 15 Insert the digital camera in the Case 16 Check the loading status 17 Seal the Case 18 Check the operation of the loaded camera 18 Perform the final checks 18 Visual Inspection 18 Water Leakage Test 19 5 Handling After Shooting 20 Wipe off any waterdrop 20 Unload the digital camera 20 Wash the Case with pure water 20 Dry the Case 21 6 Maintaining the Waterproof Funct...

Page 6: ...EN 5 En 7 Appendix 25 Specifications 25 Supplied accessories for PT E06 25 Waterproof Port 26 Optional accessories 26 PT E06_EN Book Page 5 Thursday February 26 2009 5 04 PM ...

Page 7: ...condition Neglecting the maintenance may become the cause of water leakage For how to maintenance the case refer to P 22 Silica gel 2g Hand strap Silicone grease O ring remover Case body Check that the O ring is installed on both of rear case and front case Maintenance adapter Authorized distributors list Authorized service centres list Instruction manual this manual PT E06_EN Book Page 6 Thursday...

Page 8: ... Body cap a Power switch lever b Front lid c Slide lock d Open close dial e MENU button f INFO Info display button g Air vent valve h Pickup finder i AEL AFL button j Control dial knob k Fn button l P AF target button m q Play button n u button o i button p Cross cursor button S q Cross cursor button X r Cross cursor button T s IS button t Cross cursor button W u Erase button v LCD monitor window ...

Page 9: ...con grease to the O ring section of the Waterproof Port and the Waterproof Port mounting thread on the Case Screw the Waterproof Port into the Case by turning it clockwise all the way Attach the hand strap Attach the hand strap to the Case CAUTION The Case should not be used underwater at depths that exceed 40 meters Even when the attached underwater lens port or other equipment is able to withsta...

Page 10: ...to unlock the camera table Slide the table towards the rear 1 Slide the camera table all the way into the camera table loading grooves on the front lid side of the Case Slide the camera table lock to the right to lock the camera table 2 Gently close the rear lid of the Case and close the open close dial firmly CAUTION Closing the rear lid of the Case before the camera table is inserted all the way...

Page 11: ...to the O ring between the Waterproof Port and Case 3 Ensure that the O ring of the TTL connector is attached firmly and that the cap is screwed into the connector without loosening Advance check 1 Before loading the digital camera in the Case immerse the empty Case to confirm that there is no water leakage When it is difficult water leakage can be checked by referring Water Leakage Test P 19 2 Mai...

Page 12: ...Refer to the UFL 2 instruction manual for the UFL 2 operation How to connect the underwater optical fiber cable 1 Remove the cap of the optical fiber cable insertion slot 2 Put the underwater optical fiber cable plug all the way into the optical fiber cable insertion slot CAUTION When using a non Olympus manufacturer s slave type flash with underwater optical fiber cable set the camera s built in ...

Page 13: ... to the camera Connecting the underwater TTL cable 1 Turn the TTL connector cap of the Case counter clockwise and remove it 2 Connect the underwater TTL cable optional PTCB E01 to the TTL connector on the Case 3 When not using the underwater TTL cable attach the TTL connector cap Make sure there is no foreign matter attached to the O rings inside the cap and on the TTL cable connector After that g...

Page 14: ... the camera is set to the scene mode other than the AUTO or underwater modes turning the camera ON before turning the electronic flash on would cause the camera s built in flash to pop up automatically Always be sure to turn the electronic flash ON before turning the camera ON CAUTION If the camera s built in flash pops up while the hot shoe cable is connected to the camera it will interfere with ...

Page 15: ...f the digital camera is loaded without removing the strap and lens cap the Case cannot be sealed properly and may leak 5 Remove the filter from the digital camera The digital camera cannot be loaded in the Case while the filter is attached to the lens 4 Remove the eyecup from the digital camera To improve the view of the pickup viewfinder remove the camera s eyecup before loading it in the Case Th...

Page 16: ...f the Case to the digital camera CAUTION Do not exert too much force while turning the open close dial Doing so may damage the dial 1 The eyecup and the hot shoe cover of the digital camera can be stored in the camera table 2 Attach the camera table to the tripod seat section on the bottom of the digital camera Use the camera s tripod screw hole for attaching 3 The camera table has fixed up down a...

Page 17: ...le to the digital camera slide the camera table into the Case s camera table loading groove Do not insert the camera table by force Slide it in gently while checking that the digital camera does not interfere with the internal parts of the Case 3 Gently push the Case s zoom dial and mode dial down and confirm that the zoom dial can smoothly control zooming the power switch lever can turn the digit...

Page 18: ...cable or when using a slave flash from a non Olympus manufacture check that the camera s built in flash is popped up CAUTION Before loading the digital camera attach the zoom and focus gears to the Case s zoom and focus rings Refer to the instruction manual provided with the optional underwater lens port for details If the zoom and focus gears on the lens are not properly meshed with the Case s zo...

Page 19: ...inal checks Visual Inspection After closing the case tightly check the seal between the front and rear lids and the connection between the port and case to make sure the O rings are not twisted that they sit properly in the grooves and that no foreign matter has been caught between the two parts 1 Close the rear lid gently so that the O rings do not slip out of the grooves 2 Turn the open close di...

Page 20: ...e Remove the Case from the water and check that no water has leaked at the inside of the Case 4 Next immerse the Case for 30 seconds Check carefully for air bubbles Do not perform any operation yet but just observe 5 Check that no water has entered the Case Remove the Case from the water and check that no water has leaked at the bottom of the Case 6 Next check by immersing for three minutes Check ...

Page 21: ...e case once it is opened or the port is detached Please dry these areas carefully CAUTION When opening the case or removing the port make sure no water from outside e g drops from your hair or the diving suit gets inside the case and or on the camera Before opening the case or removing the port ensure that your hands or gloves are completely clean free of sand loose fibers etc Never open the case ...

Page 22: ...ted location in the shade CAUTION Do not use hot air from a hair drier or the like for drying and do not expose the Case to direct sunlight as this may accelerate deterioration and deformation of the Case and deterioration of the O ring leading to leakage of water When wiping the Case take care not to cause scratches PT E06_EN Book Page 21 Thursday February 26 2009 5 04 PM ...

Page 23: ...ll as for damage and cracks by squeezing the entire circumference of the O ring lightly with your fingertips Remove attached foreign matter from the O ring groove with a clean cloth or a cotton swab Also remove any sand or dirt attached to any part of the Case that comes into contact with the O ring Install the O ring Confirm that no foreign matter is attached apply a thin coat of the accessory gr...

Page 24: ...at the O ring is not scratched and that its surface is flat If it is damaged in any way replace it with a brand new O ring 4 Apply lubricant on the O ring contact surface Use the lubricant remaining on the fingers to clean and lubricate the case s contact surface CAUTION Always perform maintenance of the waterproof function even when the Case has been opened every shooting Neglecting this maintena...

Page 25: ...the threaded sections with a cotton swab and apply a thin uniform layer of silicone grease provided with this case Maintenance of the TTL Connector Cap After removing the TTL connector cap from the Underwater Case be sure to clean and grease the O ring Use the maintenance adapter to remove the O ring unit from the TTL connector cap Reverse the removal procedure to re attach the O ring unit to the ...

Page 26: ...Pressure resistance Depth of down to 40 m 130 feet Main materials Main body Polycarbonate resin Open close dial release lever power switch dial mode dial control dial zoom dial camera table Polycarbonate resin Port mount pickup viewfinder frame optional bracket mount zoom dial gear TTL connector cap Aluminum Axis of operation buttons hand strap ring Stainless steel Body cap ABS resin O rings LCD i...

Page 27: ... be increased to 360 by using the optional PPZR E04 underwater focus gear The magnification immediately in front of the objective is about x0 6 PPO E02 60 m 14 54 mm 14 54 mm II Packaged with the PPZR E02 underwater zoom gear for 14 54 mm 14 54 mm II or 11 22 mm lens 11 22 mm PPO E03 60 m 50 mm Macro Manual focusing is possible using the provided PPZR E01 but the focus ring rotation angle is limit...

Page 28: ...PT E06_EN Book Page 27 Thursday February 26 2009 5 04 PM ...

Page 29: ...MEMO PT E06_EN Book Page 28 Thursday February 26 2009 5 04 PM ...

Page 30: ... Underwater Case for digital camera En Mode d emploi Caisson étanche pour l appareil photo numérique Fr Bedienungsanleitung Unterwassergehäuse für Digitalkamera De Manual de instrucciones Caja estanca para la cámara digital Sp Cs Kr PT E06 Instruction Manual PT E06_JP COVER fm 1 ページ 2009年2月26日 木曜日 午後5時14分 ...

Reviews: