background image

©2008 

http://www.olympus.com/

VS724601

Printed in China

PT-E05

取扱説明書

デジタルカメラ          用防水プロテクター

Instruction Manual

Underwater Case for digital camera

En

 

 

 

 

 

 

 

PT
-E05          Instruction Manual

PT-E05_JP-COVER.fm  1 ページ  2008年6月4日 水曜日 午前11時38分

Summary of Contents for PT-E05

Page 1: ...2008 http www olympus com VS724601 Printed in China PT E05 Instruction Manual Underwater Case for digital camera En PT E05 Instruction Manual PT E05_JP COVER fm 1...

Page 2: ...accidents involving immersion of a digital camera in water In addition expenses incurred for damage of internal materials or loss of recorded contents due to water entering the camera will not be com...

Page 3: ...s The product may deteriorate 3 Opening and closing at locations with much sand dust or dirt may impair the waterproof characteristic and cause water leakage This should be avoided 4 This product has...

Page 4: ...gn matter 5 Apply the specified silicon grease to the O ring 6 The waterproof function is not effective if the O ring is not installed correctly When installing the O ring take care that it does not p...

Page 5: ...ir or other purposes When these are used for the Case directly or indirectly with the chemicals in vaporized state they may cause cracking under high pressure or other problems z Do not perform operat...

Page 6: ...le 14 2 Advance check of the Case 15 Advance test before use 15 Check the waterproof parts of the Case 15 Advance test 15 3 Installing the digital camera 16 Check the digital camera 16 Battery Confirm...

Page 7: ...ng 29 Wipe off any waterdrop 29 Unload the digital camera 30 Wash the Case with pure water 31 Dry the Case 31 6 Maintaining the Waterproof Function 32 Remove the O ring 32 Procedure 32 Remove any sand...

Page 8: ...er if accessories are missing or damaged Silica gel Hand strap Silicone grease O ring remover Case body Check that the O ring is normal Waterproof cap maintenance adapter Instruction manual this manua...

Page 9: ...ont cap a Power switch lever b Front lid c Slide lock d Open close dial e INFO Info display button f MENU button g S Erase button h q Play button i Air vent valve j Pickup finder k AEL AFL button l Co...

Page 10: ...nd strap Attach the hand strap to the Case CAUTION The Case should not be used underwater at depths that exceed 40 meters Even when the attached underwater lens port or other equipment is able to with...

Page 11: ...s lens window When pressing the shutter lever press it gently so that there will be no movement of the camera The Case has a mode dial knob that that functions the same way as the mode dial of the dig...

Page 12: ...2 14 54 mm 11 22 mm Controllable Not Controllable Only autofocusing is possible PPO E03 50 mm Macro Not Controllable Controllable 2 Manual focusing is possible but the MF ring rotation range is limite...

Page 13: ...parately available UFL 2 underwater flash to the Case using an underwater optical fiber cable optional follow the procedures below Put the underwater optical fiber cable plug all the way into the opti...

Page 14: ...cult to loosen and remove CAUTION If you cannot disconnect the TTL cable do not use force Contact Olympus for support 1 Turn the hot shoe cable connector cap inside the case counterclockwise to remove...

Page 15: ...ly into the camera s tripod screw hole For details see How to attach the camera table to the digital camera P 19 of this manual 4 Slide the camera table all the way into the camera table loading groov...

Page 16: ...g of the TTL cable connector is attached firmly and that the cap is screwed into the connector without loosening Advance test 1 Before loading the digital camera in the Case immerse the empty Case at...

Page 17: ...lly charged battery before each dive CAUTION If the digital camera is loaded without removing the strap and lens cap the Case cannot be sealed properly and may leak Handle the digital camera carefully...

Page 18: ...make sure the camera is operating correctly Open the Case 1 Slide and hold the slide lock towards the arrow direction 1 and turn the open close dial counter clockwise 2 2 Turn the open close dial to...

Page 19: ...lens For details refer to the instruction manual for the PPO E05 Example 2 Attaching the optional underwater zoom focus gears PPZR E03 E04 E05 to the lens For details refer to the instruction manual...

Page 20: ...e camera in the Case with the camera s built in flash popped up Refer to the UFL 2 instruction manual for the UFL 2 operation 1 The eyecup and the hot shoe cover of the digital camera can be stored in...

Page 21: ...mera is set to a scene mode other than the AUTO or underwater modes turning the camera ON before turning the electronic flash on would cause the camera s built in flash to pop up automatically Always...

Page 22: ...ial and mode dial on the Case pulling out the mode dial also pulls up the power switch lever so that they do not get in the way while loading the digital camera At this time set the orientation of the...

Page 23: ...fere with the internal parts of the Case CAUTION The built in flash should be popped up before loading the camera in the Case Once the case has been sealed the built in flash cannot be popped up from...

Page 24: ...ng the digital camera attach the zoom and focus gears to the Case s zoom and focus rings Refer to the instruction manual provided with the optional underwater lens port for details Adjust the position...

Page 25: ...power be switched ON OFF Is the mode dial of the camera controllable When using an external electronic flash with a TTL cable check that the hot shoe cable is connected properly and that the camera s...

Page 26: ...he grooves 2 Turn the open close dial clockwise The Case is sealed when the position of the slide lock comes right above CAUTION If the open close dial is not fully turned the Case will not be sealed...

Page 27: ...ion After closing the case tightly check the seal between the front and rear lids and the connection between the port and case to make sure the O rings are not twisted that they sit properly in the gr...

Page 28: ...of the Case Is there any water trickling down 4 Next immerse the Case for 30 seconds Check carefully for air bubbles Do not perform any operation yet but just observe 5 Check that no water has entered...

Page 29: ...he image can be done by using the pick up finder or the LCD monitor When using the LCD monitor to confirm use the Live View function by pressing the u button Gently press the shutter lever When pressi...

Page 30: ...ing suit gets inside the case and or on the camera Before opening the case or removing the port ensure that your hands or gloves are completely clean free of sand loose fibers etc Never open the case...

Page 31: ...y do not interfere with removal of the camera and take out the camera CAUTION After opening the Case always place it so that the O ring surface is facing up If the O ring surface is faced down foreign...

Page 32: ...igh water pressure is applied locally Before washing the Case with water remove the digital camera from it Operate the shutter lever and various buttons of this product in pure water to remove salt ad...

Page 33: ...rcumference of the O ring lightly with your fingertips Remove attached foreign matter from the O ring groove with a clean cloth or a cotton swab Also remove any sand or dirt attached to any part of th...

Page 34: ...es or unevenness After spreading the lubricant check visually and by touch that the O ring is not scratched and that its surface is flat If it is damaged in any way replace it with a brand new O ring...

Page 35: ...ctions with a cotton swab and apply a thin uniform layer of silicone grease provided with this case Maintenance of the TTL Connector Cap After removing the TTL connector cap from the waterproof cap be...

Page 36: ...foreign objects such as dust or hair 8 Be sure to insert the silica gel for prevention of fogging Use the exclusive silica gel for Olympus underwater cases 9 Confirm that the open close dial for use...

Page 37: ...er or the like and do not dry the Case under direct sunlight Exposure to high temperatures or direct sunlight may cause deformation discoloration or breakage of the Case and deterioration of the O rin...

Page 38: ...damage cracking or loss of elasticity Q10 What precautions need to be taken for proper maintenance of the Case A10 Pay special attention to the following items 1 Do not use the following chemicals for...

Page 39: ...is provided with the PER E02 PPO E04 60 m 8 mm Fisheye The focus ring angle can be rotated by 360 by using the optional PPZR E05 underwater focus gear PPO E05 40 m 14 42 mm Packaged with the PPZR E06...

Page 40: ...power switch dial mode dial control dial zoom dial camera table Polycarbonate resin Port mount pickup viewfinder frame optional bracket mount zoom dial gear TTL connector cap Aluminum Axis of operati...

Page 41: ...PT E05_EN Book Page 40 Wednesday June 4 2008 12 34 PM...

Page 42: ...l Underwater Case for digital camera En Mode d emploi Caisson tanche pour l appareil photo num rique Fr Bedienungsanleitung Unterwassergeh use f r Digitalkamera De Manual de instrucciones Caja estanca...

Reviews: