background image

E-6

After inserting the camera, turn the camera table

lock lever of the PT- E series case all the way
clockwise to lock the camera table, and then
push in the zoom dial on the PT-E series case.

MENU

Push in the PT- E series case’s power switch

dial and mode dial knob. Turn the power switch
dial and mode dial knob and confirm that they
can control the camera power ON-OFF and
mode switching. Connect the hot shoe mount
section of the hot shoe cable that has been
connected to the PT-E series case to the hot
shoe of the camera.

 

Attach the rear lid of the PT- E series case and
lock the four buckles (two diagonally located
buckles first, and then the other two diagonally
located buckles). Underwater shooting is now
possible.

Confirm that the camera’s power switch is OFF.

While pulling out the zoom dial on the PT-E
series case, slide the camera table with camera
attached as far as it will go into the camera
table mount on the inner side of the case’s front
lid. 

MENU

Pull out the zoom
dial further.

CAUTION:

When this product is used in combination with a zoom lens, zooming of cannot be controlled

after the camera has been loaded in the case. Be sure to set the zoom ring of the lens to the
desired focal distance before loading the camera in the case.

PER-E01̲En  2005.6.1  3:02 PM  ページ6

Summary of Contents for PER-E01

Page 1: ...or PT E Series Mode d emploi Bague d extension sous marine pour la s rie PT E Bedienungsanleitung Unterwasser Zwischenring f r PT E Serie Manual de instrucciones Aro de extensi n para usar debajo del...

Page 2: ...rom the camera and lens Do not disassemble or modify this product This may result in injury The silicone O ring grease is not edible CAUTION Do not leave this product where it may be exposed to high t...

Page 3: ...ween the PT E series waterproof case and the PPO E series waterproof lens port Before mounting first make sure that no foreign matter is attached then apply a thin layer of the provided silicone O rin...

Page 4: ...ible below the threaded section of the PER E01 Screw in until there is no gap Align the threaded section of the PER 01 with the port mount thread on the PPO E series lens port Hold the PT E series cas...

Page 5: ...g the PPO E about 90 degrees counterclockwise If the PPO E is screwed in too tight wrap it with a piece of rubber or other slip resistant material After loosening the PPO E series lens port point its...

Page 6: ...lens cap or filter is attached to the lens or the strap is attached to the camera remove them as well Lift the PT E series case s power switch dial mode dial knob and zoom dial and turn the case s cam...

Page 7: ...a Attach the rear lid of the PT E series case and lock the four buckles two diagonally located buckles first and then the other two diagonally located buckles Underwater shooting is now possible Confi...

Page 8: ...h a clean lint free cloth or cotton swab Also remove any foreign matter from the O ring contact surfaces the port mount thread on the PT E series case and the O ring groove of the PPO E series lens po...

Page 9: ...USA 24 7 online automated help http www olympusamerica com support Phone customer support Tel 1 888 553 4448 Toll free Our phone customer support is available from 8 am to 10 pm Monday to Friday ET E...

Page 10: ...2005 OLYMPUS IMAGING CORP PER E01_01 Printed in Japan...

Reviews: