Page 1: ...EVIS X1 Installation Guide Ver 4 0 Olympus Europa SE Co KG 1...

Page 2: ...tion New preparation A Sekiya S Tominaga 2 0 2020 06 24 5 9 11 12 25 36 70 85 Information updated nCare ISM Product A Sekiya N Ito 3 0 2021 01 25 108 120 Added OIP 1 cabling T Dekker H van Duellen 4 0...

Page 3: ...tion 4 Set up device on WM NP3 5 Installation and setting 6 CV 1500 wiring setup peripheral equipment excluding US center 7 CV 1500 wiring and setting US center 8 CV 1500 wiring and setting CV 190 190...

Page 4: ...4 1 System organization...

Page 5: ...lation using the following system configuration Monitor OEV321UH OEV262H OEV261H US Center EU ME1 EU ME2 CV 1500 UPD 3 UCR Video recorder IMH 200 IMH 20 IMH 10 nCare Trolley WM NP2 WM NP3 OFP 2 Printe...

Page 6: ...6 2 Package contents...

Page 7: ...941 White cap set MAJ 2431 Foot holder 4pcs with a pattern Cable color sheet Instructions for use OSS Instructions for use installation Instructions for use operation CV 1500 Package contents CV 1500...

Page 8: ...8 3 Precautions for installation...

Page 9: ...80 CV 190 CV 190PLUS CV 290 382 91 489 EU ME1 430 185 500 EU ME2 445 184 495 IMH 10 370 108 5 413 IMH 20 370 167 5 413 IMH 200 370 150 390 Maximum size mm Product name Width Height Depth nCare 371 87...

Page 10: ...tray WM NP2 WM NP3 3 Precautions for installation Supplementary Info When CV 1500 on the mid shelf is placed on the pattern the collar of the connector protrudes from the front end of the mid shelf Ho...

Page 11: ...maximum load kg Top shelf 20 20 mid shelf plate 30 5 31 Base shelf 35 35 Product name Weight kg CV 1500 19 4 CV 190 CV 190PLUS CV 290 10 7 EU ME1 23 EU ME2 22 5 Product name Weight kg OEP 4 9 OEP 5 9...

Page 12: ...e so that the total power does not exceed the maximal power of the isolation transformer Product name Rated power VA OEV321UH 182 OEV262H 112 OEV261H 160 CV 1500 600 CV 190 CV 190PLUS CV 290 150 Produ...

Page 13: ...ice s power code Connecting to a 3 core medical outlet directly or via an isolation transformer of the workstation In order to reduce the electrostatics charge perform wiring operations for while conn...

Page 14: ...tput terminals during installation Ensure that the device to be connected is switched off then connect the SDI cable If connecting with the power on the product or peripheral equipment may damaged Whe...

Page 15: ...15 4 Set up device on WM NP3...

Page 16: ...for each shelf plate see 3 Precautions for installation 16 Monitor arm Place the monitor Top shelf Install the video processor When combining CV 1500 and CV 190 190PLUS 290 place CV 190 190PLUS 290 u...

Page 17: ...17 5 Installation and setting...

Page 18: ...nd setting Rear of CV 1500 video terminal Rear of CV 1500 Remote terminal Rear of OEV321UH video terminal OEP 6 Rear Video Remote Terminals Tips for installation and setting up Setting for recording i...

Page 19: ...ut terminal 1 Y C input terminal 2 CV inputs Y C are used to connect to CV 190 190PLUS 290 3 HD SD input SDIs terminals 4 CV inputs SDIs are used to connect to CV 190 190PLUS 290 1 2 3 1 2 3 4 Output...

Page 20: ...flushing pumps for endoscopy Color video printers etc Keyboard etc CV interface converter External video system center 1 2 4 5 3 6 The main remote terminals used for wiring are as follows Remote Term...

Page 21: ...2429 12G SDI cable 8 5M 3G SDI MAJ 2430 3G SDI cable 1 5M 1080p 1080i SD MAJ 2015 3G SDI cable 3 0M MAJ 2016 3G SDI cable 8 5M Convention al products MAJ 1951 SDI cable 2 5M 1080i SD MAJ 1912 SDI cab...

Page 22: ...r endoscopic image Setting User setting Release Pre freeze Capture area HD HD or SD Supplement Regarding Capture area Images are saved based on the setting as follows Observation monitor Entire screen...

Page 23: ...t Setting Parameter Setting User setting Release Pre freeze Record ext source ON ON Setting User setting Release Pre freeze Input terminal for external source HD SD input SDI Select the terminal that...

Page 24: ...24 6 CV 1500 wiring and setting Peripheral equipment excl US center...

Page 25: ...of Contents Wiring setup with peripheral devices Keyboard OEV321UH OEV262H OEV261H OEP 6 OEP 5 OEP 4 MAJ 1916 IMH 200 MAJ 1916 IMH 20 MAJ 1916 IMH 10 MAJ 1916 nCare ISM Product UPD 3 PSCU UPD 3 PSCU O...

Page 26: ...1995 MAJ 1710 A dedicated cable is required for the connection Refer to 7 CV 1500 Wiring and Setting US center for wiring and setup Compatible Keyboard Menu Key on the Keyboard cannot be used Use the...

Page 27: ...D signal HD 1080p 4K OEV321UH MENU Preset Load Preset B C B C MENU Input Output Configuration Port A Input Select 12G SDI 1 12G SDI 1 Caution The 12G SDI cable is required to output 4K image 12G SDI1...

Page 28: ...p HD 1080p OEV262H MENU Preset Load Preset B C B C PORT A SDI1 SDI1 Caution To use OEV262H as an observation monitor set CV 1500 image output to HD 1080p or less because OEV262H is not compatible with...

Page 29: ...HD 1080i OEV261H PRESET OEV261H FILE LOAD I I INPUT OEV261H port A SDI1 SDI1 Caution To use OEV261H as an observation monitor set CV 1500 image output to HD 1080i or less because OEV262H is not compa...

Page 30: ...Release 2 save location Portable memory Portable memory Video printers OEP 6 MENU System setup Remote setup REMOTE3 Device type CV CV MENU System setup Input setup Input signals Auto Auto Caution To...

Page 31: ...ation or Release 2 save location Portable memory Portable memory Video printers OEP 5 SIGNAL SETUP INPUT SETUP INPUT SEL SDI SDI SIGNAL SETUP INPUT SETUP HD SD SEL Auto Auto Caution To connect with OE...

Page 32: ...g If this is done Video printer type will be Not connected MAJ 2363 can be used instead of MAJ 1916 For the wiring and setting when using MAJ 2363 refer to CV 290 OEP 4 MAJ 2363 Refer Setting model St...

Page 33: ...Video recorder IMH 200 Settings System Settings Devices Accessories Devices REMOTE1 No Device Processor Type 1 Settings Rec Function Setting VIDEO PORT A PORT A PORT A Caution Since IMH 200 is not co...

Page 34: ...ble memory Video recorder IMH 20 System settings Function settings Device Remote 2 No Device Processor type 1 User settings Select input SDI Caution Since IMH 20 is not compatible with 4K and HD 1080p...

Page 35: ...y Video recorder IMH 10 System settings Function settings Device Remote 2 No Device Processor Type 1 User settings Select input SDI Caution Since IMH 10 is not compatible with 4K and HD 1080p set CV 1...

Page 36: ...connected Not connected SETTING INFORMATION 1 Caution Since nCare is not compatible with 4K and HD 1080p set CV 1500 output to HD 1080i or less nCare record status is not shown in CV 1500 Remote cont...

Page 37: ...tings User Settings PIP POP Select CV ext source HD SD input SDI HD SD input SDI UPD 3 Menu System settings System Remote Connection CV remote LINK IN Supplement When LINK connected UPD 3 s front pane...

Page 38: ...p Peripherals 2 Select PIP POP device CV CV Settings User Settings PIP POP Select CV ext source HD SD IN SDI Y C IN Supplement Please refer to the External Image Record Setting for how to record PSCU...

Page 39: ...h OEV321UH PSCU HD SD input Y C output SDI output LINK IN CLV LINK OUT CLV UPD 3 5 6 7 Setting model Step Default After change CV 1500 Setting System setup Video output 12G SDI OUT 4K HD signal HD 108...

Page 40: ...to the External Image Record Setting for how to record UPD 3 PSCU images Reference Since the PIP has been entered into the CV UPD 3 PSCU screen is displayed on the monitor by performing the following...

Page 41: ...ing User Setting New Entry or Edit Remote Switch Customized key Flushing pump SETTING INFORMATION Reference Assign the function of OFP 2 operation to the Remote Switch Custom Button as optional You ca...

Page 42: ...Air CO2 Setting user setting new entry or edit Equipment settings Air flow level High Optional Setting user setting new entry or edit Remote Switch Customized key Air supply Air supply CO2 insufflatio...

Page 43: ...43 7 CV 1500 wiring and setting US Center...

Page 44: ...s EU ME2 type A EU ME2 type A1 EU ME2 type E1S Precautions when connecting EU ME1 EU ME1 Type Selection Flow Outline of EU ME1 setting type using one monitor Outline of EU ME1 setting type using two m...

Page 45: ...tion type by reference to the flow below Type A Type A1 Recommend ation NO 2 or more monitors YES Monitor 1 EVIS US switch Monitor 2 Fixed EVIS YES NO Monitors 1 Fixed EVIS Monitor 2 Fixed US In EVIS...

Page 46: ...ame as EVIS images Selectable in the setting Same as EVIS images Simple diagram Remarks Wiring Use MAJ 1951 2 5M to connect CV 1500 and EU ME2 P in P In US mode No sub screen display In US mode No sub...

Page 47: ...ions such as lightning strikes can cause noise in images 1 2 3 4 OEV321UH CV 1500 EU ME2 MAJ 1995 DIP switching setup for MAJ 1995 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ...

Page 48: ...etup Peripherals 2 US multi monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entry or edit PIP...

Page 49: ...OEV262H DIP switching setup for MAJ 1995 List of Cables 4 12G SDI1 IN 12G SDI output 4K HD KEYBOARD EUS OFP HD SD input SDI Keyboard Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI...

Page 50: ...ed Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or Edit Rel...

Page 51: ...OEV321UH CV 1500 EU ME2 MAJ 1995 OEV262H DIP switching setup for MAJ 1995 List of Cables 4 Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2...

Page 52: ...ripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entry or edit PIP POP Display meth...

Page 53: ...Ultrasound center MAJ 1710 When the serial number of the keyboard is combined with a number smaller than the following Keyboard may not work Please check MAJ 1710 serial number prior to delivery If y...

Page 54: ...pe E1S NO Monitors 1 Fixed EVIS Monitor 2 Fixed US Type B1 YES Type B Type A 2 or more One Be ready for SDI converters Number of monitors would like to share a monitor for EVIS US Be ready for SDI con...

Page 55: ...Simple diagram Remarks Wiring Need an SDI converter Simple P in P Maneuverability Stored image Options Options Outline of EU ME1 setting type using one monitor 55 The outline of each connection type i...

Page 56: ...Subscreen No indication Maneuverability Additional wiring is required according to the operation of monitors for US when ME1 is not used Additional wiring is required according to the operation of mon...

Page 57: ...dical device 1 2 3 4 5 DIP switching setup for MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 1951 SDI cable 2...

Page 58: ...System setup Peripherals 2 US multi monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entry or...

Page 59: ...MAJ 1710 EU ME1 1 2 4 3 DIP switching setup for MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MH 985 Y C cable 2 9...

Page 60: ...rminal HD SD input SDI Y C input Setting System setup Peripherals 2 US multi monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON...

Page 61: ...IP switching setup for MAJ 1710 Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 2430 3G SDI cable 1 5M MAJ 2015 3G SDI cable 3 0M MAJ 20...

Page 62: ...abled Enabled Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry...

Page 63: ...DIP switching setup for MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 2430 3G SDI cable 1 5M MAJ 2015 3G SDI c...

Page 64: ...2 US multi monitor Fixed EVIS output Disabled Enabled Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS U...

Page 65: ...non medical device OEV262H 1 2 3 2 4 5 DIP switching setup for MAJ 171 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 19...

Page 66: ...eripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or Edit Release Pre freeze Record ex...

Page 67: ...1500 MAJ 1710 EU ME1 OEV262H 1 2 2 4 3 DIP switching setup for MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MH 9...

Page 68: ...t Disabled Enabled Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New e...

Page 69: ...69 8 CV 1500 wiring and setting CV 190 190PLUS 290 And peripheral equipment...

Page 70: ...S 290 IMH 200 MAJ 2363 CV 190 190PLUS 290 IMH 20 MAJ 2363 CV 190 190PLUS 290 IMH 10 MAJ 2363 CV 190 190PLUS 290 nCare ISM product CV 190 190PLUS 290 UPD 3 CV 190 190PLUS 290 PSCU CV 190 190PLUS 290 PS...

Page 71: ...error E301 will occur The patient information display setting can be changed only by Olympus service personnel Please check by the following methods and contact service personnel prior to the establi...

Page 72: ...V 190 190PLUS 290 sets are automatically changed If it is necessary note the setting beforehand If it is placed in WM NP2 the height of the top shelf needs to be changed NP3 does not need to be change...

Page 73: ...190 190PLUS 290 front panel Operate from CV 1500 touch panel It may cause errors such as white balance cannot be completed and CV 190 190PLUS 290 error display etc If it occurs restart both CVs The wa...

Page 74: ...Peripheral Device Remote Cables MAJ 1918 1 It connects to the adapter in CV 1500 and the CV of MAJ 2363 5 Connecting Peripheral Device Remote Cables MAJ 1918 2 Connects to the Keyboard in CV 190 190PL...

Page 75: ...S Video Out CV inputs Y C Product symbol Name 1 MAJ 1951 SDI cable 2 5M MAJ 1912 SDI cable 8 5M 2 MAJ 985 Y C video cable 2 95M MAJ 987 Y C cable 15M 3 MAJ 1941 Light source cable 4 MAJ1918 Device Re...

Page 76: ...OEV321UH MENU Preset Load Preset B C B C MENU Input Output Configuration Port A Input Select 12G SDI 1 12G SDI 1 Caution The 12G SDI cable is required to output 4K image 12G SDI1 IN 12G SDI output SET...

Page 77: ...NU Preset Load Preset B C B C PORT A SDI1 SDI1 Caution To use OEV262H as an observation monitor set CV 1500 image output to HD 1080p or less because OEV262H is not compatible with 4K format SDI1 IN 3G...

Page 78: ...OEV261H FILE LOAD I I INPUT OEV261H port A SDI 1 SDI 1 Caution To use OEV261H as an observation monitor set CV 1500 image output to HD 1080p or less because OEV262H is not compatible with 4K format SD...

Page 79: ...ve location Portable memory Portable memory Video printers OEP 6 MENU System setup Remote setup REMOTE3 Device type CV CV MENU System setup Input setup Input signals Auto Auto Caution Since OEP 6 is n...

Page 80: ...se 2 save location Portable memory Portable memory Video printers OEP 5 Signal setup input setup input selection SDI SDI Signal setting input setting HD SD selection Auto Auto Caution Since OEP 5 is n...

Page 81: ...rinter Connecting Model In the opposite order of setting If this is done Video printer type will be Not connected Setting model Step Default Setting parameter CV 1500 Setting System setting Peripheral...

Page 82: ...recorder IMH 200 Settings System Settings Devices Accessories Devices REMOTE1 No Device Processor Type 1 Settings Rec Function Setting VIDEO PORT A PORT A PORT A Caution Since IMH 200 is not compatibl...

Page 83: ...Video recorder IMH 20 System settings Function settings Device Remote 2 No Device Processor Type 1 User settings Select input SDI Caution Since IMH 20 is not compatible with 4K and HD 1080p set CV 150...

Page 84: ...MH 10 System settings Function settings Device Remote 2 No Device Processor Type 1 User settings Select input SDI Caution Since IMH 10 is not compatible with 4K and HD 1080p set CV 1500 output to HD 1...

Page 85: ...1 Caution Since nCare is not compatible with 4K and HD 1080p set CV 1500 output to HD 1080i or less nCare record status is not shown in CV 1500 Remote control function is under development in ISM Tou...

Page 86: ...tings User Settings PIP POP Select CV ext source HD SD input SDI HD SD input SDI UPD 3 Menu System settings System Remote Connection CV remote LINK IN Supplement When LINK connected UPD 3 s front pane...

Page 87: ...PIP POP device CV CV Settings User Settings PIP POP Select CV ext source HD SD IN SDI Y C IN Supplement Please refer to the External Image Record Setting for how to record PSCU images Reference Since...

Page 88: ...H 985 Y C cable 4 5 MAJ 1942 Communication cable 0 7M MAJ 1948 Communication cable 1 8M 6 7 MAJ 1898 CLV UPD cable List of Cables OEV321UH CV 1500 UPD 3 LINK OUT LINK IN UPD PSCU 4 2 Y C input PSCU HD...

Page 89: ...List Info PIP POP PIP ON It is able to switch UPD 3 or PSCU image by using PIP input select button Setting model Step Default After change CV 1500 Setting System setup Video output 12G SDI OUT 4K HD...

Page 90: ...es 1 2 3 4 OEV321UH EU ME2 MAJ 1995 DIP switching setup for MAJ 1995 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 1951...

Page 91: ...Setting System setup Peripherals 2 US multi monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New en...

Page 92: ...12G SDI1 IN 12G SDI output 4K HD KEYBOARD EUS OFP HD SD input SDI Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 2430 3G SDI Cable 1 5...

Page 93: ...t Disabled Enabled Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New e...

Page 94: ...MAJ 1995 List of Cables 4 Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 1951 SDI cable 2 5M 3 SMF 405 Monitor cable 0 5M 4 MAJ 1586 H...

Page 95: ...itch EVIS US switch Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entry or edit PIP POP Display method PIP PIP Setting Users Presets New...

Page 96: ...of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 1951 SDI cable 2 5M MAJ 1912 SDI cable 8 5M MAJ 1464 SDI cable 22M 3 MAJ 1586...

Page 97: ...i monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entry or edit PIP POP Display method PIP PIP...

Page 98: ...of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MH 985 Y C cable 2 95M MAJ 987 Y C cable 15 M 3 MAJ 604 DF remote cable 2 M MAJ 60...

Page 99: ...tting System setup Peripherals 2 US multi monitor Fixed EVIS output Disabled Disabled Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Presets New entr...

Page 100: ...12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 2430 3G SDI cable 1 5M MAJ 2015 3G SDI cable 3 0M MAJ 2016 3G SDI cable 8 5M 3 MAJ 1951 SDI cable 2 5M MAJ 1912 SDI ca...

Page 101: ...Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or Edit Release Pre freeze Record e...

Page 102: ...l Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 2430 3G SDI cable 1 5M MAJ 2015 3G SDI cable 3 0M MAJ 2016 3G SDI cable 8 5M 3 MH 985 Y C cable 2 95M...

Page 103: ...ut Disabled Enabled Setting System setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New...

Page 104: ...or MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MAJ 1951 SDI cable 2 5M MAJ 1912 SDI cable 8 5M MAJ 1464 SDI cabl...

Page 105: ...d EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or Edit Release Pre freeze Record ext source ON OFF Setting Users Prese...

Page 106: ...MAJ 1710 List of Cables Product symbol Name 1 MAJ 2426 12G SDI cable 1 5M MAJ 2428 12G SDI cable 2 9M MAJ 2429 12G SDI cable 8 5M 2 MH 985 Y C cable 2 95M MAJ 987 Y C cable 15 M 3 MAJ 604 DF remote c...

Page 107: ...setup Peripherals 2 12G SDI OUT 4K HD Fixed EVIS Fixed EVIS Setting System setup Peripherals 2 3G SDI OUT HD EVIS US switch EVIS US switch Settings User Presets New entry or edit Release Pre freeze Re...

Page 108: ...108 9 CV 1500 wiring and setting ENDO AID CADe...

Page 109: ...109 Cabling Standard Setup ENDO AID CV 1500 OEV321UH...

Page 110: ...E 110 ENDOBASE PC 3G SDI OUT Documentation with ENDOBASE Screenshot with CADe marker Images acquired by ENDOBASE will never include any CADe markers around detected polyps Check that the resolution fr...

Page 111: ...ation with ENDOBASE Screenshot without CADe marker Images acquired by ENDOBASE which were not frozen during acquisition will contain a marker surrounding the detected polyps Check that the resolution...

Page 112: ...Alternative with Scopeguide OIP 1 CV 1500 UPD 3 112...

Page 113: ...Setup 3a OIP 1 CV 1500 UPD 3 IMH 200 113...

Page 114: ...Setup 3b OIP 1 CV 1500 UPD 3 IMH 10 20 114...

Page 115: ...Case 4 OIP 1 CV 1500 UPD 3 nCare 115...

Page 116: ...Case 5 OIP 1 CV 1500 UPD 3 nCare EUS 116...

Page 117: ...Case 6 CV 1500 OEV321UH OIP 1 PSCU 117...

Page 118: ...Case 7 CV 1500 OEV321UH OIP 1 PSCU nCare 118...

Page 119: ...Case 8 CV 1500 OEV321UH OIP 1 PSCU HVO 400ST 119...

Page 120: ...Case 9 CV 1500 OEV321UH OIP 1 UPD 3 PSCU 120...

Page 121: ...Case 10 CV 1500 OEV321UH OIP 1 UPD 3 PSCU Care 121...

Page 122: ...Case 11 CV 1500 OEV321UH OIP 1 UPD 3 PSCU HVO400 122...

Page 123: ...123 10 Appendix...

Page 124: ...ase Pre freeze Release recording range Entire screen Endoscopic image Setting User setting Release Pre freeze Record ext source ON OFF ON OFF Release 1 Release 2 External Images Reliease User setting...

Page 125: ...ub Screen Delete Retain Elimination mainte nance Wiring type A B US OFF EVIS PIP ON US ON EVIS PIP OFF When the system setup Image Record US image record during EVIS is OFF US images will not be store...

Page 126: ...Delete Retain No indication No indication Stored image when connecting the US center Wiring type A1 and B1 When the system setup Image Record US image record during EVIS is OFF US images will not be s...

Page 127: ...ea Entire screen Endoscopic image When the system setup Image Record US image record during EVIS is OFF US images will not be stored With the user setup combination the images are stored as follows No...