Olympus CELON ELITE ESG-200 Quick Reference Manual Download Page 4

4

  CELON ELITE QUICK REFERENCE GUIDE

A S S I G N   F O O T   S W I T C H

STEP 1

: Tap Foot Switch on the All Screen. 

The Assign Foot Switch Screen is displayed.

STEP 2: 

Select the desired foot pedal (blue for 

coagulation/yellow for cutting) in the bipolar 
or monopolar plane. Tap Return to confirm the 
settings. The All Screen is displayed.

All Screen

Assign Foot Switch Screen

Assign Foot Switch Screen

Summary of Contents for CELON ELITE ESG-200

Page 1: ...QUICK REFERENCE GUIDE PROCEDURE SETTING RECOMMENDATION ...

Page 2: ...s a quick reference guide only It is not a substitute for reading and learning the entire Operators Manual and or Instructions For Use IFU provided with the CELON ELITE Olympus cannot encourage or recommend any actions that deviate or are not covered by the IFU ...

Page 3: ...lus Procedure name blank if no procedure selected Output socket indicator bipolar monopolar Neutral electrode indicator Mode button Menu button Foot Switch button Foot switch indicator Select Procedure button Autostart indicator Wattage CELON ELITE User Interface with Touchscreen Main Components ...

Page 4: ...l Screen The Assign Foot Switch Screen is displayed STEP 2 Select the desired foot pedal blue for coagulation yellow for cutting in the bipolar or monopolar plane Tap Return to confirm the settings The All Screen is displayed All Screen Assign Foot Switch Screen Assign Foot Switch Screen ...

Page 5: ...S STEP 1 Tap on either the yellow or blue mode button on the All Screen The Mode Screen is displayed STEP 2 Select the desired output mode on the Mode Screen Shown example Pure RFITT STEP 3 Set output power level by tapping and All Screen Mode Screen Set Screen ...

Page 6: ...e the current output settings tap Menu on the All Screen The Select Menu screen is displayed STEP 2 Tap Save Procedure in the Select Menu screen STEP 3 Enter a name for the procedure settings Tap OK to save the procedure name All Screen Select Menu Screen On Screen Keyboard ...

Page 7: ...ath Pure Fine RFITT 15 W adult 18 W smaller turbinates e g children Soft palate stiffening CelonProSleep Plus Pure RFITT 12 W Note The higher the power setting the smaller the coagulation volume The optimal setting may vary depending on the individual anatomy and the area of application Please refer to the procedure guide for further information about the treatment procedure ...

Page 8: ...60 Little carbonization and adhesion Autostart selectable Cut Fine Cut 120 W 470 Low spark intensity for small thermal effect Pure Cut 120 W 530 Medium spark intensity for medium thermal effect Strong Cut 120 W 560 High spark intensity for large thermal effect Monopolar Coag Soft Coag 120 W 250 Little carbonization and adhesion Forced Coag 120 W 2000 Spark allows coagulation also with relatively s...

Page 9: ...r Banana Plug 1 pin plug 4 mm diameter Bovie Plug 1 pin plug 8 mm diameter Split or Non Split Neutral Electrodes Plugs with 2 sockets 2 5 mm socket diameter Socket spacing 10 mm For monopolar HF cables Neutral BIPOLAR MONOPOLAR NEUTRAL Disclaimer Any content or information Content presented herein is illustrative in nature and does not guarantee or represent specific information outcomes or result...