45MG —Getting Started Guide

Measurement Screen (No Waveform Option)

Measurement Screen (Waveform Option)

Freeze indicator

Gain level

Thickness value

Previous thickness

Units

Alarm indicator

Mode (MIN/MAX)

and value

Power indicator

(battery, USB, or AC)

MicroSD memory card

indicator

Mode and update rate

ID bar

(with Datalogger option)

Zoom indicator

Rectification indicator

Echo detection marker

Delay value

Mode (MIN/MAX)

and value

Freeze indicator

Alarm indicator

Gain level

Range value

[WAVE ADJ] parameter

Power indicator

(battery, USB, or AC)

MicroSD memory card

indicator

Mode and update rate

ID bar

(with Datalogger option)

Previous thickness

Thickness value

Units

Summary of Contents for 45MG

Page 1: ...p the documentation CD in a safe accessible location Safety Signal Words Indicates an imminently hazardous situation calling attention to a procedure practice or the like which if not correctly performed or adhered to could result in death or serious personal injury Indicates a potentially hazardous situation calling attention to a procedure practice or the like which if not correctly performed or...

Page 2: ... memory card USB communication connector Transmit Receive transducer connector 2 Transmit Receive transducer connector 1 To avoid the risk of electric shock do not touch the inner conductors of the T R 1 and T R 2 connectors Up to 200 V may be present on the inner conductor ...

Page 3: ...al protective rubber boot if installed 4 Turn the battery door lock half a turn counterclockwise to the unlock position 5 Remove the battery compartment cover 6 Remove the batteries 7 Insert three new batteries into the battery compartment making sure to observe the correct polarity for each battery 8 Ensure that the gasket inside the battery compartment cover is clean and in good condition 9 Rein...

Page 4: ...actory default settings for the transducers purchased The default settings use an approximate sound velocity for the stainless steel test block provided with the instrument 1 Connect the transducer to the transducer cable and then plug the cable into the T R 1 connector on the top of the instrument 2 Press to turn on the instrument 3 Press 2nd F FREEZE XDCR RECALL 4 In the menu select DEFAULT SING...

Page 5: ...G Ultrasonic Thickness Gage User s Manual P N DMTA 10022 01EN or contact Olympus Keypad Functions The 45MG comes with either an English or international keypad The functions on both keypads are identical Many keys on the international keypad contain pictograms instead of text labels In the 45MG user documentation keypad keys are referred to using the English label displayed in bold and within brac...

Page 6: ... battery USB or AC MicroSD memory card indicator Mode and update rate ID bar with Datalogger option Zoom indicator Rectification indicator Echo detection marker Delay value Mode MIN MAX and value Freeze indicator Alarm indicator Gain level Range value WAVE ADJ parameter Power indicator battery USB or AC MicroSD memory card indicator Mode and update rate ID bar with Datalogger option Previous thick...

Page 7: ...de 7 Instrument Hardware Components Protective rubber boot optional Stand optional Strap rings at the four corners of optional rubber boot Color display Keypad I O door protecting USB connector Transducer connectors Power key ...

Page 8: ...m Printed in the United Stated of America 2012 by Olympus All rights reserved All brands are trademarks or registered trademarks of their respective owners and third party entities DMTA 10024 01EN U8778520 Rev A September 2012 Printed on Rolland Hitech50 which contains 50 post consumer fiber 50 ...

Reviews: