Installation 

The boiler must be mounted on a flat wall which is sufficiently robust to take 
the weight of the boiler. If the wall is of combustible material it must be 
protected by a sheet of non-combustible material of thickness not less than 25 
mm (1 in). 

Note: If the boiler is to be fitted into a house of timber frame construction, 
advice is available from your trade organisation or local Gas Region. 

The boiler is designed for use with an open vented central heating system 
and/or indirect domestic hot water system. IT MUST NOT BE CONNECTED 
TO A DIRECT CYLINDER. 

The boiler may be installed in any room, although particular attention is drawn 
to the requirements of the latest I.E.E. Wiring Regulations and, in Scotland, 
the electrical provisions of the building regulations applicable in Scotland, with 
respect to the installation of the boiler in a room containing a bath or a 
shower. 

Where the installation of the boiler will be in an unusual position, special 
procedures may be necessary and BS5376:2 and BS5546 give detailed 
guidance on this aspect. 

A cupboard or compartment used to enclose the boiler must be designed and 
constructed specifically for this purpose. An existing cupboard or 
compartment may be used provided that it is modified for the purpose. 

Details of essential features of cupboard/compartment design including airing 
cupboard installations are given in BS5376:2 and BS5546. 

Boiler dimensions, minimum clearances and connection details are shown in 
frames 1, 12 and18: 

Fit one or more drain cocks to enable the water system to be fully drained. 

Note: THE PUMP MUST BE WIRED BACK TO THE BOILER, see wiring 
diagrams, frames 46 and 47. For low head system see frame45. 

Data 

Heat inputs and outputs together with burner setting pressures are given in 
frame 42. 

Summary of Contents for 20/35F

Page 1: ...d from 5 86 to 10 26 kW 20 000 to 35 000 Btu h The boiler must be installed in accordance with The Gas Safety Regulations 1972 The Gas Safety Installation and Use Regulations 1984 Local Building Regulations By Laws of the local Water Undertaking I E E Wiring Regulations Detailed recommendations are stated in the following British Standard Codes of Practice CP331 3 1974 BS5376 2 1976 BS5546 1979 BS...

Page 2: ...both poles or preferably a fused 3 pin plug and shuttered outlet socket adjacent to the boiler Fuse the supply at 3 amp Mains cable 0 75 mm2 24 x 0 20 mm The external wiring between the appliance and the electrical supply shall comply with the latest lEE Wiring Regulations and any local regulations which apply The appliance must be earthed In the event of an electrical fault after installation of ...

Page 3: ... an aluminium shield of at least 750 mm 30 in in length should be fitted to the underside of the gutter pipe or painted surface If the terminal is fitted less than 2 m 6 6 ft above a balcony above ground or above a flat roof to which people have access then a suitable terminal guard must be provided A type K2 protective guard is available from Tower Flue Components Ltd at Vale Rise Tonbridge Kent ...

Page 4: ...e in Scotland with respect to the installation of the boiler in a room containing a bath or a shower Where the installation of the boiler will be in an unusual position special procedures may be necessary and BS5376 2 and BS5546 give detailed guidance on this aspect A cupboard or compartment used to enclose the boiler must be designed and constructed specifically for this purpose An existing cupbo...

Page 5: ...n is connected to the in connection under the boiler and the temperature rise across the boiler is 11ºC 20º F In the event of any fault occurring during the commissioning of the boiler a fault finding guide is available in the maintenance instructions Page 2 ...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ...VE FOR COMPLETE SAFETY OF OPERATION THAT THE OUTER CASE IS PROPERLY FITTED CHECK THAT THE FOUR CASE FIXING SCREWS ARE TIGHTENED SUFFICIENT TO COMPRESS THE SEALING GASKET DO NOT RUN THE BOILER WITH THE CASE REMOVED Back Page Page 11 ...

Reviews: