background image

12

Operating (continued)

 

 

 

 

   

 

   

 

 

WARNING: 

A leak test must be performed annually or if a part of the gas system is replaced.

LEAK TESTING OPERATION 

 

 

 

 

   

 

   

 

 

WARNING: 

Never use an open flame to check for gas leaks. Be certain no sparks or open flames are in the area 

while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to property, serious 

bodily injury, or death.

LEAK TESTING: 

1, Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.

3, Apply several drops of solution where hose attaches to regulator.

4, Apply several drops of solution where regulator connects to cylinder.

5, Turn cylinder valve ON.

2, Make sure all fire pit and light valves are OFF

If bubbles appear at any connection, there is a leak.

1, Turn cylinder valve OFF.

2, If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles continue appearing,

pls contact 855-600-9294 for assistance.

3, If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak test. If you continue

to see bubbles after several attempts, cylinder valve is defective, and contact 855-600-9294 for assistance. 

If NO bubbles appear at any connection, the connections are secure.

NOTE: 

Whenever gas connections are loosened or removed, you must perform a complete leak test .  

Hose/Regulator

  Connection

Regulator/Cylinder

  Connection

Summary of Contents for GYM-81008

Page 1: ...turned off DO NOT REMOVE DEFACE OR OBLITERATE THIS LABEL EXCEPT AS AUTHORIZED BY ANSI NFPA 58 DANGER Do not store a spare LP cylinder under or near a barbecue grill or other heat sources NEVER fill a...

Page 2: ...ain this manual for future reference WARNING result causing property damage personal injury or loss of life WHAT TO DO IF YOU SMELL GAS Do not try lighting any appliance Do not touch any electrical sw...

Page 3: ...or LP Gas Cylinders or the standard for Cylinders Spheres and Tubes for Transportation of Dangerous Good and Commission CAN CSA B339 as applicable The LP gas supply cylinder must be provided with a cy...

Page 4: ...must be replaced prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified servi...

Page 5: ...ve all parts refer to the hardware and package contents list If you are missing parts please contact after services for further assistance NOTE Please read and understand the entire l l a t s n i r o...

Page 6: ...E 1 Description Leg A Leg B Leg C Leg D Metal Lid Part Quantity I 1 J 1 K L 1 M 1 Description Side Panel Back panel Side Panel with Window Gas tank support Cross Bar F 1 Fire Glass G H Table top with...

Page 7: ...using one M6 x 10 mm Bolt AA Assembling the front door frame 7 1 2 Assembling the legs Assembly D H AA AA B A C D G Attach the Legs A B C to the Table Top with Burner G by using eight M6x10mm Bolts A...

Page 8: ...o not tighten the bolts at this step Attach the control panel to the side panel with window K by using four M5x12 mm bolts CC and tighten them 4 Assembling the side panel Attach the side panel I to th...

Page 9: ...s at this step Attach the back panel J to the legs B C by using B C AA AA C AA BB Attach the gas tank support L to side panels K I with four M6x16 mm bolts BB Attach cross bar M to the bottom of back...

Page 10: ...al Lid E must be removed when the burner is in cylinder by tightening the screw in the gas tank support L Connect the hose and regulator to the cylinder Place the fire glass F operation Wait until it...

Page 11: ...rating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before each use and at least annually by a qualified service person More fre...

Page 12: ...ion where regulator connects to cylinder 5 Turn cylinder valve ON 2 Make sure all fire pit and light valves are OFF If bubbles appear at any connection there is a leak 1 Turn cylinder valve OFF 2 If l...

Page 13: ...sts A clogged tube can lead to a fire WARNING If the burner does not light within 10 seconds turn the valve off and wait 5 minutes for gas to dissipate before repeating the procedure Shut Down 1 To ex...

Page 14: ...ree and clean from combustible materials gasoline or other flammable vapors and liquids At least once a year the unit should be inspected for the presence of spiders spider webs or other insects Air f...

Page 15: ...ther the thermocouple or valve is faulty The thermocouple must have time to heat up Hold the knob in for 30 seconds after the burner lights then release The unit will shut down if winds are greater th...

Page 16: ...PV 101 BE...

Page 17: ...5 8 3 4 9...

Page 18: ...F E C D B G 1 3 2 X2 X2 X2 X2 X2 X8 X2 X20 X4 X24 M6x90 M6x35 4 5 X8 X8 6 7 X1 X1 L R...

Page 19: ...6 1 2 4 5 B E 4 5 E C 2 3 D A 2 3 B A D...

Page 20: ...6 5 6 7 7 8 C 2 3 1 3 G F...

Page 21: ...9...

Page 22: ...PV 103 BE...

Page 23: ...5 8 3 4 9...

Page 24: ...F E C D B M N 1 O X8 X1 X2 X1 X1 X2 X1 X1 X1 X2 2 3 X14 X14 4 5 X8 X8 6 7 X1 X1 M6 M8 M8 M6 M6x35 M6x90 M8...

Page 25: ...6 1 2...

Page 26: ...6 5 6 7 8 7 8...

Page 27: ...9...

Page 28: ...PV 104 BE...

Page 29: ......

Page 30: ...X4 X4 X24 X24 M6 M6 M6 M6 M6...

Page 31: ...3 4 5 6 6 3 4 5...

Page 32: ...7 5 6 6 6 7 8 8...

Page 33: ...PV 106 BE...

Page 34: ...5 6 3 4 7...

Page 35: ...F E C D B 1 2 4 3 X4 X1 X1 X1 X1 X1 X9 X4 X9 X4 M6 M6 M6x35 M8 5 6 X1 X1 M6 M8...

Page 36: ...6 1 2...

Page 37: ...7...

Reviews: