background image

Quick Reference 

   

CM 70 Cash Register 

 

 

Olympia    5.2005 

Page 10 

All Rights Reserved 

 

 
- Table, continued - 

Note: The standard settings appear in bold print. 

System option no. 

Status no. 

Setting 

Zero skip printing for Z-report 

11 

No zero skip printing for Z-report 

 

Zero price of a PLU or department not permitted 

12 

Zero price of a PLU or department permitted (default) 

 

No special European rounding 

1 European 

rounding: 

Swiss 

2 European 

rounding: 

Swedish 

13 

3 European 

rounding: 

Danish 

 

Printing of an additional bill permitted 

14 

Printing of an additional bill not permitted 

 

Z1 and Z2 counters are not deleted after Z-financial report printout 

15 

Z1 and Z2 counters are deleted after Z-financial report printout 

 

Grand Total is not deleted after Z1 financial report printout 

16 

Grand Total is deleted after Z1 financial report printout 

 

Grand Total is not printed on the financial report 

17 

Grand Total is printed on the financial report 

 

0 Calculator 

mode 

18 

1 Journal 

mode 

 

Basic currency is the local currency (amount 

÷

 conversion factor) 

19 

Basic currency is foreign currency (amount 

×

 conversion factor) 

 

Refunds are printed on the financial report 

20 

Refunds are not printed on the financial report 

 

 

The system options set can be printed out.  

Input 

Display 

Confirm by pressing 

 

Printing system settings
Set the key to PRG 

Press 

9

 6 times, conclude by 

pressing 

q

999999 

9999,99 

q

 

 

Clearing errors 

Incorrect entries and error status (acoustic signal) can be cleared by pressing 

g

 

Registration according to departments 

Enter price without decimal point (max. 7 digits). 

 

 Price 

Department 

 

 

 

 

PPPPPPP 

 

 

 

Or: If the same PLU should be registered several times: 

 

No. of PLUs 

 

Price 

Department 

 

 

NN 

PPPPPPP 

A

 

 

 

 

The sum of NN x PPPPPPP is limited to the maximum capacity of the cash register. 

 

Summary of Contents for CM 70

Page 1: ...CM 70 Quick Reference O Y L MPIA SINCE 1903 www olympia vertrieb de...

Page 2: ...e la presente el fabricante declara que este aparato est conforme a lo dispuesto en las directivas y normas vigentes n De fabrikant verklaart hierbij dat het apparaat voldoet aan de bepalingen in de r...

Page 3: ...ransportation of the cash register Transport locks Before the cash register can be put into operation remove any transport locks installed and store them for future use Important transport information...

Page 4: ...the paper reel Replace the printer lid Paper reel The paper reel is required when the receipt should be wound onto it Change the system setting no 18 to 1 1 Open the printer lid 2 Remove the paper ree...

Page 5: ...without memory deletion Z reports with memory deletion Programming Calculation Note Loss of data and jamming of the cash register are possible in Z and PRG operating modes Only use these modes when y...

Page 6: ...10106 0101 06 m Programming the time Example 9 30 a m Input Display Confirm by pressing Set the key to PRG Enter the time as 4 digits hhmm Confirm by pressing h 0930 9 30 h Programming tax rates A max...

Page 7: ...tax rates 000 DEP operates without fixed price free pricing alternatively Enter the fixed price Example 2 DEP1 is an itemised department at tax rate 2 7 and without a fixed price Input Display Confir...

Page 8: ...ng Status 0 fixed price Status 1 free pricing Set the key to PRG Press e Enter the PLU no to be pro grammed and confirm by pressing f 12 P12 0 12 f Enter the PLU status assign by pressing the correspo...

Page 9: ...to the 24 hour format Input Display Confirm by pressing Set the key to PRG The system options are entered as 2 or 3 digits The input is confirmed by pressing c 40 40 c Note The standard settings appe...

Page 10: ...Total is deleted after Z1 financial report printout 0 Grand Total is not printed on the financial report 17 1 Grand Total is printed on the financial report 0 Calculator mode 18 1 Journal mode 0 Basi...

Page 11: ...ed Conclude receipt p PPPPPPP q Foreign currency payment When all the PLUs have been registered press the p key to display and print the subtotal Enter the foreign currency identification and press k...

Page 12: ...rices which have already been concluded can be reverted d Refund function is activated Complete the registration to be reverted Conclude with q Other functions m Cash register is opened e For cash pay...

Page 13: ...0 CH 001 20 00 RA 001 20 00 PO 51 13 1 002 300 00 CA 400 00 13 45 009 Date Z1 counter 3 digit Number of registrations in department 1 Sales for department 1 Number of registrations in department 2 Sal...

Page 14: ...he 4 digit password press n SEC CODE A password has been programmed for the clerk Enter the clerk number Then enter the 3 digit password Conclude by pressing R What to do if the cash register does not...

Page 15: ...ug Check whether the paper roll is inserted correctly or there is a foreign body in the printer mechanism Remove it if present Caution Remove the foreign body very carefully Do not use a knife screwdr...

Reviews: