Values
Programming steps
Screen
LT4
Under the Technician model (L2)
Set Resin Volume
1. Select “Set Resin Volume
” parameter by (▼▲)
Set Resin Volumet
2. Press “validation” and adjust
(▼▲) the resin volume (LT4)
x L
3. Press “validation” to return to the Technician mode ( L2)
LT5
Under the Technician model (L2)
Set Brine
D. Type
1. Select “Set Brine D. Type” pa
rameter by (▼▲)
Set Brine D.
Type
2. Press “validation” and select up-flow or down-flow (LT5)
●
up-flow
3. Press “validation” to return to the Technician mode ( L2)
○
down-flow
LT6
Under the Technician model (L2)
Set Backwash Time
1. Select “Set Backwash Time
” parameter by (▼▲)
Set Backwash Time
2. Press “validation” and adjust time according to the
Annex I
(LT6)
XX Minutes
3. Press “validation” to return to the technician mode (L2)
LT7
Under the Technician model ( L2)
1. Select “Set B.S.R.T
” parameter by (▼▲)
Set B.S.R.T
Set B.S.R.T
2. Press “validation” and adjust time according to the
Annex I
(LT7)
XX Minutos
3. Press “validation” to return to the Technician mode (L2)
LT8
Under the Technician model (L2)
1. Select “Set B.R.Time
” parameter by (▼▲)
Set B.R. Time
Set B.R. Time
2. Press “validation” and adjust time according to the
Annex I
(LT8)
XX:XX Minutes
3. Press “validation” to return to the Technician mode (L2)
LT9
Under the Technician model ( L2)
1. Select “Set F.R.Time
” parameter by (▼▲)
Set F.R.Time
Set. F.R. Time
2. Press “validation” and adjust time according to the
Annex I
(LT9)
XX Minutes
3. Press “validate” to adjust seconds
4. Press “validation” to return to the Technician mode ( L2)
LT10
Under the Technician model (L2)
1. Select “Set F.R.Time” parameter by (▼▲)
Interval B.W. Times
Interval B.W. Times
2. Press “validation” and ad
just (▼▲) the backwash interval (LT10)
F-00
3. Press “validation” to return to the Technician mode (L2)
LT11
Under the Technician model (L2)
1. Select “Set F.R.Time” parameter by (▼▲)
Interval Regen. D.
Interval Regen. D.
2. Press “validation” and adj
ust (▼▲) the days between Regenerations (LT11)
30 days
3. Press “validation” to return to the Technician mode (L2)
OLYMPIA PLUS-CEASA 47
Summary of Contents for 160 V HF UF
Page 1: ...MANUAL DE INSTRUCCIONES ES INSTRUCTION MANUAL EN MANUEL D INSTRUCTIONS FR 1...
Page 2: ......
Page 30: ......
Page 31: ...INSTRUCTION MANUAL EN OLYMPIA PLUS CEASA 1...
Page 32: ......
Page 61: ...MANUEL D INSTRUCTIONS FR OLYMPIA PLUS CEASA 61...
Page 62: ......
Page 90: ...90 OLYMPIA PLUS CEASA...
Page 91: ...OLYMPIA PLUS CEASA 91...