Illustration: Install 3 ball valves to connect the control valve and inlet/outlet pipeline.
The valve A is connected between the inlet/outlet; the valve B is connected with the
inlet of the control valve; the valve C is connected in the outlet of the control valve.
When repair the tank, please open the valve A and close the valve B and valve C; When
normally use, please close the valve A and open the valve B and valve C.
-
Connecting drain valve must be within 2m. height above this. The optional
overflow line should be above the drain. Installing cutting system water drain lines is
prohibited.
-
Each pipeline should be supported with fixed holder independently, avoiding
the control valve be damaged by bearing the gravity from the pipeline.
Notice: Please make sure the drain line and overflow line is connected and close
to sewer, making the waste water flow into the sewer rapidly.
8.3
Setting and usage
8.3.1
Display equipment with LCD
These series of valves allow the program to select two modes, User mode (Foreground) or the Technical mode
(Background).
In the User mode (Foreground), the user can set the time of day, time of Regeneration and water hardness input.
In the Technical mode (Background) can set the cycle times of Regeneration Anti-washing,Brine slow aspiration
and washing, filling the salt tank and rinsing of the resins, and the valve model,Filtration indicate whether or
decalcification, Volumetric type or time if the resins volume, counter-flow mode or co-current and the days
between regenerations.
OLYMPIA PLUS-CEASA 43
Summary of Contents for 160 V HF UF
Page 1: ...MANUAL DE INSTRUCCIONES ES INSTRUCTION MANUAL EN MANUEL D INSTRUCTIONS FR 1...
Page 2: ......
Page 30: ......
Page 31: ...INSTRUCTION MANUAL EN OLYMPIA PLUS CEASA 1...
Page 32: ......
Page 61: ...MANUEL D INSTRUCTIONS FR OLYMPIA PLUS CEASA 61...
Page 62: ......
Page 90: ...90 OLYMPIA PLUS CEASA...
Page 91: ...OLYMPIA PLUS CEASA 91...