Gas density less than 0.97kg/CBM, then it's lighter.
4.1.3 The position should be far away from shocking, shattering, strong
electromagnetic interference. Around the position, there should be at
least 0.3m empty place.
4.1.4 The position should be within 1m around the possible gas leakage
area, such as valve, pipe connection point, gas outlet place. Please try to
install it nearer to the above places, but avoid influencing the working of
the other equipments. Please avoid the environment of high temperature
and humidity. Also please keep it from water swashing, oil and
mechanical damage. Please also consider the convenience of
maintenance and calibration.
4.1.5 For large scale detection, we suggest install 1pc every 10-12
square meters, so as to get the best detection result.
4.2 Dimensions
4.3 Installation methods
Note:
Fix the detector with sensor head downwards. According to the
installation place, fix the detector onto the wall or gas pipes. Details as
follows:
Method 1 Wall mounted:
According to the device dimension, choose a
Fig. 2 Dimension
Drawing