background image

ELECTRICAL CONNECTIONS (after the mains interruption)

1

2

3

4

5

6

7

Unfasten the two side cover screws and remove the 
plastic cap by sliding it gently.
Install  the  gaskets  and  make  holes  at  the  center  of 
each gasket by using a small screwdriver. Pass the 
round cable through the gaskets.
Pass  the  communication  cables  through  the  holes 
and connect them as shown in the picture when there 
are  other  luminaires  to    be  connected  to  the  line 
(minding the correct polarity).
If the luminaire you installed is the last one connect 
the cable to one of the two inputs, as shown on the 
picture (minding the correct polarity).
Address the device though the dipswitch according 
to the table on page 5.
Replace the removed parts in the previous steps. 

SURFACE MOUNTING ON A WALL (single sided)

Install the included plastic bracket on the wall (figure 
1). Remove the aluminum bracket from the luminaire 
and use the two supplied mounting screws to install 
the aluminum bracket to the plastic bracket (figure 2). 
Slide the luminaire to the aluminum bracket and use 
the  bolt  on  the  center  (*),  to  stabilize  the  luminaire 
(figure 2). 

CEILING MOUNTING (double sided)

Remove the aluminum bracket from the luminaire and 
install it with the included spacers, screws and plugs in 
the  ceiling  (page  3).  Slide  the  luminaire  to  the 
aluminum bracket and use the bolt on the center (*), to 
stabilize the luminaire (figure 4). 
Power on the device at the end of the installation (see 
GR-8600 manual)

.

INSTALLATION INSTRUCTIONS

(*)

 First, hand tighten it and then, 

use pliers to tighten it little bit 
more (not all the way).
 

Page 2 from

 

5

1

2

3

+L -L

4

+L

-L

Cable 

entry

Screws

9230

26

00

5

_09_00

1

8

9

Reviews: