LAMP TESTING

AUTOMATIC DURATION TEST

Erasing errors is accomplished with a prolonged 
pressing of the TEST button (>5 sec) when the unit 
is connected to the mains power supply. The fault 
indicated with the indicator  LAMP FAULT / BATT. 
FAULT will be erased. If the cause of the fault has 
not  been  restored  (i.e  burned  lamp)  then  the 
indicator will light again. If the fault was caused by 
a low emergency duration and you erase the error 
then  this  will  be  indicated  again  during  the  next 
duration  test  after  6  months.  In  this  case  (for 
duration  errors)  it  is  vital  to  replace  the  battery 
before erasing the error (the error is automatically 
erased  if  the  mains  power  and  the  battery  are 
disconnected).

AUTOMATIC EMERGENCY CIRCUIT TEST

The unit automatically tests the emergency circuit 
every 15 days (if the battery and mains power are 
connected) . During this test the lamps are turned 
ON  for  3  seconds  using  the  batteries.  In  some 
cases this function might not be acceptable (i.e in 
cases this function might not be acceptable (i.e in 
cinema  theaters)  so  the  installer  must  take  this 
into account during the installation.

This  test  is  conducted  every  6  months  by 
simulating a power failure, if the battery and mains 
power supply are connected. The unit lights the 
lamps using the charged battery and counts the 
time until the stated duration. If the lamps are ON 
during the end of the test then the unit is restored 
to  its  normal  operation  (lamps  OFF  and  battery 
charging). If the lamps go OFF before the end of 
the  test  then  the  unit  is  restored  to  its  normal 
operation  but  the  LAMP  FAULT  /  BATT.  FAULT 
indicator is lit to show that there is a problem with 
the battery and that the battery must be replaced. 
Let it be noted that this duration test is also done 
during  every  long  power  failure.  If  the  power 
failure lasts for a long time and the luminaire has 
entered  the  BATTERY  CUTOFF  mode  and  the 
duration  measured  is  not  correct  then  the  fault 
indicator will light when the power is restored.

ERASING ERRORS

The  luminaire  tests  the  good  condition  of  the 
lamps in emergency mode and warns the user for 
probable malfunction. If a lamp is found faulty then 
the LAMP FAULT indicator starts to blink. To verify 
which lamp is faulty use the TEST button. If the 
faulty  lamp  is  replaced  then  the  error  is 
automatically restored and the indicator is turned 
OFF.

The  WL  luminaire  models  have  the  ability  to 
communicate  over  the  air  with  Olympia’s  control 
panels  for  wireless  emergency  luminaires.  The 
luminaires  can  also  communicate  with  a 
PC/laptop  through  a  gateway  (Ethernet,  Wi-Fi, 
USB).  For  more  information,  please  refer  to 
Wireless  Emergency  Lighting  guides,  available 
on the company’s website.

    procedure must be done only by qualified

Wireless communication

WARNING !!!

1. Every test, installation or maintenance

    personnel.

3. The replacement of the battery and the

    light source must be done using parts of

2. The unit must be connected to the mains

    accordingly.

    the same type, by the manufacturer or by
    a competent person.

4. If the luminaire must be isolated from the

    mains power supply for more than 2
    months then the batteries must be
    disconnected by removing the battery

    power supply using a line fuse rated

    connectors.

5. 

I

s  not  allowed  to  discard  batteries  in  to 

t  i

common  trash  bins,  they  must  be 
discarded  only 

in  battery  recycling 

points. Do not incinerate.

 

Battery replacement 

It  can  be  done  only  by  a  competent  person 
and after the mains interruption.

1.

 Follow the step 2 

o

f the installation

    

procedure.

2.

 Disconnect the 

cables

 and remove the

    

old battery.

3.

 Connect the new battery with the same

    

type (step 

3

 of the installation procedure)

    

and place it in the position

 

of the old

 

one.

4.

 Follow the step 

6

 of the installation

    

procedure and power the device.