6.3. TEST. 

System check , call  point  and  programming  names 

Insert   the   technical   code   (1111) and   using the 

FAULT EVENTS

 key scroll to the 

 

indication  

TEST. 

Press 

ENTER  

and  the  Display shows  the  indication

 

------

.

In  this mode we can  test the system and check  if the call points  which  are mounted 
on  every  room  are  operating  and  corresponding    to  the    numbers  that  we  have 
programmed  for every room. 

For  this    test  to  be  conducted  two  people  are  required.  Also  some  form  of 
communication between them is also required (E.g. Wireless radio , intercom). 
One person goes from room to room and presses the call points. The other person 
verifies that all the call points are operating and that   that there is a correspondence 
between the call point and the displayed value. 

When the call  point  is pressed,  the  Display shows  the  number of the zones - room 
(e.g. P  1) and the  room  name  which  has  been programmed (e.g. 101) . 

At   the end of the process   press   successively   the   

ESC   

key   so   as   to   exit   the 

programming procedure.

Page 12 from 18

7.  SIGNAL NUMERATOR PANEL OPERATION MODE. 

This  operation mode is  for  the  user  and  is  very  simple. 
When  the mounting and programming process has finished and the system has been 
tested and is operating then the user can do the following operations. 

7.1. Starting position operation. 

The  system  is  ready  to  accept  the  calls  of  the  zones - rooms and on the control 
keyboard  - unit we have the following indications. 
The  Display  shows the indication  

---- 

 and  the   

POWER 

LED is lighted (green led)

.

 

7.2. Calling  from a call point.

If  a  call point is pressed in any   room - zone,  the  keyboard shows  the room  number   
which  was  programmed  to  correspond  to  the  specific  call  point.  The    buzzer  also   
sounds. 

7.3. Calling  from more than one  call points.

If   two or more call points are pressed then   the   keyboard   successively shows   the 
numbers from the  call points that were  pressed and the  

SIGNAL

 indication led lights 

to indicate  that we have multiple  calls. The  buzzer also sounds.

7.4. Resetting/cancelling indications and calls.

To reset/cancel  calls  press  the  

ON - OFF BUZZER / HELP 

key  and the call that is 

shown will be reset/canceled. 

921746000_09_003

Summary of Contents for BS-746

Page 1: ...www olympia electronics gr SA A R RT CE CERTIFICATE VALID SYSTEM EN ISO 9001 2008 ...

Page 2: ...od 6 2 5 Ccod 6 2 6 UsuP 6 2 7 dLoA 6 2 8 r AL 6 3 TEST 7 SIGNAL NUMERATOR PANEL OPERATION MODE OPERATING 7 1 Start position operation 7 2 Calling from one call point 7 3 Calling from more than one call points 7 4 Resetting indications calls 7 5 Resetting all the calls with a code 7 6 Viewing the communication faults and the software version of the keyboard 7 7 Fault indication signals 8 PRESENCE ...

Page 3: ...48 zones rooms To monitor 48 zones rooms we must use a BS 746 keyboard and a BS 748 panel 48 zones These 2 devices are connected to each other with four 4 wires fig 1 3 2 Systems from 49 to 240 zones rooms If we want to expand the zones rooms from 49 to 240 we have to increase the number of the panels according to the zones rooms that we want to cover For each 48 zones we must use an extra BS 748 ...

Page 4: ...48 slave BS 748 slave BS 748 slave BS 746 address 5 address 6 address 7 address 8 address 9 A A A A A A A A A A A A Fig2 Connections shematic diagram with one keyboard BS 746 and 5 panels BS 748 signal numerator panel 48 240 zones 921746000_09_003 ...

Page 5: ...address 7 BS 748 slave address 8 BS 748 slave address 9 Fig3 Connection diagram with4 keyboards BS 746 and 5 panels BS 748 for a complete enumerator panel system BS 746 slave address 2 BS 746 slave address 3 BS 746 slave address 4 A A A A A A A A A A A A A A A Page 5 from 18 921746000_09_003 ...

Page 6: ...d software version 4 5 The Up and Down arrow keys ALARM EVENTS FAULT EVENTS show us the inputs which have been activated Also with these keys we can scroll through the menus 4 6 The ON OFF BUZZER HELP key is used to eliminate reset individual calls INDICATORS 4 7 The POWER LED is lighted when the panel is supplied with 230V AC 4 8 The ERROR LED is lighted when there is fault in the communications ...

Page 7: ...the ENTER key again and the indication 1 appears this is the preset name which will appear on the Display every time that someone calls us from the zone room 1 If we want to change the name of the room we have to type the number which we want to appear e g 101 and press the ENTER key to confirm the process The Display shows the indication P 2 which is the next number of the memory second terminal ...

Page 8: ... using the FAULT EVENTS key scroll to the menu item S UP and press ENTER The indication Clr Is shown on the display Press the ENTER key and the indication _ _ _ 1 is shown This means that this keyboard has a value of 1 Depending on this value the calls are reset cancelled as shown in the table below If we want to change the value press the required number 0 to 5 and then press ENTER so the keyboar...

Page 9: ...e key FAULT EVENTS scroll to the indication S UP press the ENTER key and scroll to the indication buzz using the arrow keys Then press the ENTER key and the display shows the indication _ _ _ 1 This means that the buzzers sound mode is 1 The table below explains the different sound mode that are available VALUE PROGRAMMING Buzzer deactivated Signal numerator panel operation mode default 5 short so...

Page 10: ...oard Master This programming operation recognizes all the peripheral devices panels repeater keyboards which are connected to the main keyboard Master This process is necessary and is the first step which we have to do when the panel operates for first time Insert the technical code 1111 and using the FAULT EVENTS key scroll to the indication S UP press the ENTER key and using the arrow keys scrol...

Page 11: ...programs in sequence e g P1 P2 P3 P4 P240 At the end of the process press successively the ESC key so as to exit the programming procedure 6 2 8 r AL Clearing and resetting the keyboard to default conditions This programming operation resets all the names which have been programmed for every room and returns these values to their default settings Insert the technical code 1111 and using the FAULT ...

Page 12: ... the programming procedure Page 12 from 18 7 SIGNALNUMERATOR PANELOPERATION MODE This operation mode is for the user and is very simple When the mounting and programming process has finished and the system has been tested and is operating then the user can do the following operations 7 1 Starting position operation The system is ready to accept the calls of the zones rooms and on the control keybo...

Page 13: ... use this mode we must connect a terminal in each room This can be done using for example a room activation switch that has a volt free relay contact This contact is then connected to the zone of the panel To program the rooms follow the directions in section 6 1 If we want to correspond the rooms with alias names or numbers e i Zone 1 has a corresponding alias room number 101 In order for the sys...

Page 14: ...dure This procedure last for a few minute and the display shows the units that are searched for by the keyboard in sequence U2 U3 U4 U9 If the keyboard detects a unit it will report it e i C _ _ 5 The buzzer sounds briefly and the detected unit is stored in memory After finishing the detection process press the ESC key as many time as it is required in order to exit programming mode 9 4 System che...

Page 15: ... CLEAR key resets all the calls 5 The code resets all the calls Change the technical code Change the user code Recognize units which are connected with the central keyboard Master Update information on the repeater keyboards from the main keyboard master Resetting all options on the keyboard to default settings INDICATION INDICATION INDICATION INDICATION BS 746 TECHNICAL MENU FLOW CHART COMMAND ME...

Page 16: ...Call point Page 16 from 18 Call point Call point Call point Call point Call point 921746000_09_003 ...

Page 17: ...ll points that are connected to the terminal blocks 8 24 are connected in the same manner as the call points on the terminal blocks 1 7 The call points that are connected to the terminal blocks 25 43 are connected in the same manner as the call points on the terminal blocks 44 48 921746000_09_003 ...

Page 18: ...Page 18 from 18 921746000_09_003 ...

Reviews: