background image

Technical Specifications

BS-634

4 zone fire

detection panel

BS-636

6 zone fire

detection panel

Mains power supply

220-240VAC  50/60Hz

48VA

One 12V 

 7Ah maximum

Lead acid sealed 

Stabilized power supply  13.8V / max. 400mA

36 hours (without using the outputs  24V_M and 24V_P)

Two  24V circuits that are monitored for open and short circuit conditions 

(maximum current 300mA each). Each output is protected  

with a self-reseting electronic fuse.

 26VDC ( ±3VDC)  permanent output  

The output is protected with a self-reseting electronic fuse.

with maximum current output  0.3 A

ABS - polycarbonate

Consumption

Battery type

Charging circuit

Autonomous duration

Zone circuits

Alarm circuits

Output   24P

Construction material

4 circuits monitored for

short and open circuit

conditions (maximum current 35mA)

6 circuits monitored for

short and open circuit

conditions (maximum current 35mA)

 26VDC ( ±3VDC)  reset interrupted output  with maximum current output  0.3 A

The output is protected with a self-reseting electronic fuse.

Output  24M

 One Aux relay and 

each. Under no circumstances should voltages or currents outside limits

 be connected.  All relays output must be protected  with a fuse of the same rating.

6 relays contacts are rated at  30VDC  and 5A maximum 

Outputs AUX, Zone Relays

325 x 240 x 85 mm

2040gr (4030gr with battery) 

ΕΝ 54-2, ΕΝ 54-4

2 years

Dimensions

Weight

Produced in accordance to

Guarantee

Open collector output signal  as specified in 8.8 of EN 54.2 (max. 30VDC/6mA)

Output  F_OUT

Up to  95% relative humidity

Humidity

o

0 to 50  C

Operation temperature

The total output current ( zones circuits, siren circuit, outputs 24P, 24M) 

must not exceed 700mA.

Total load

IP 30

Cables for fire rated cables systems such a FIP200,MICC, PYROFIL

The panel has only one serviceable fuse to protect incoming mains supply. 

This fuse is 

  must be replaced with a fuse 

of the same type and rating

T250mAL250V

IP

Cables

Fuse ratings

4 circuits monitored for

short and open circuit

conditions (maximum current 35mA)

6 circuits monitored for

short and open circuit

conditions (maximum current 35mA)

25VA

Page 9 from 9

921636000_09_023

Summary of Contents for BS-634

Page 1: ...ired battery for the panels is the type 986 12V 7Ah All functions and indications are according to European Norms 54 2 and EN 54 4 Top cover retaining screws Control Keyboard and indication leds Mount...

Page 2: ...ss level 1 has all the functions that can be done directly from the user without using a code These operations are Buzzer silence Buzzer reactivation If an alarm of fault condition is issued then the...

Page 3: ...inute The default setting of this relay is set to be activated from a general alarm and immediately with no delay In this programming mode if the keys 1 and 2 are pressed we can toggle the LEDs ON or...

Page 4: ...ross section cable of 1 5mm Page 4 from 9 Figure 2 Connecting 4 detector bases to zone 1 Each base can accept BS 655 BS 660 or BS 667 detectors A remote indication LED BS 572 is connected to one of th...

Page 5: ...lt condition issued by the panel If it is required that this output be activated by an alarm condition then we must set the MODE switch 2 to the ON position To meet the requirements paragraph 8 8 of E...

Page 6: ...power on During installation use grounded antistatic wrist band to protect this equiment form ESD The panel must be installed permanetly It is not allowed to connect the device directly to any socket...

Page 7: ...wer Zone disable and General disable LEDs blink If an alarm is manually given by either activating a BS 536 call point or by activating a smoke detector with smoke or simulated smoke particles the cor...

Page 8: ...d from VdS Also VdS controls the production under CPD number Page 8 from 9 BS 636 6 zone fire detection panel KOLINDROS PIERIAS GREECE Provided options Output to fire alarm device s 0786 CPD 21016 10...

Page 9: ...put is protected with a self reseting electronic fuse Output 24M One Aux relay and each Under no circumstances should voltages or currents outside limits be connected All relays output must be protect...

Reviews: