If normal sensitivity is selected then care must
be taken that house pets do not have access
to furniture that is near or at the same height as
the detector in order to avoid false triggering.
Physical obstructions such as walls, furniture,
separators, glass dividers e.t.c must be
avoided because they will degrade the
detection area of the detector.
The room’s ambient temperature is a factor
that plays a significant role in the detection
range of the detector. In hot summer months
the detection range is degraded and can be
compensated if we select high sensitivity
during these months.
The device is unsuitable for outdoor use
.
9m
.
9m
.
12
m
.
Surveillance zone distribution in the horizontal plane
Surveillance zone distribution in the vertical plane
Page 2 of 5
2,4
m
.
To remove the top cover insert a flat blade
screwdriver in the slot. Push the screwdriver gently
to unlock the latch and remove the cover
, as shown
in the photo below.
After removing the top cover it is suggested to
gently remove the circuit board by removing its
retaining screw
, as shown in
the
photo
3 of
page 3.
Take care not to touch the IR sensor surface. This
will affect is operation.
Photograph
4 (
page 3
)
shows the interior of the
plastic base as well as the cable entry and
mounting hole positions.
To mount the unit to the wall, increase the hole
diameter of points
Α
to
4
mm
.
using a suitable drill
bit and mount the unit using the supplied mounting
accessories.
The same can be done if we require to mount the
unit at an angle or in a corner. Drill out points
Β
,
on
the side that will have contact with the wall and use
the supplied mounting accessories.
In corner
mounting
, it will require two additional screws and
the corresponding plugs.
When mounting has been finished reinstall the
circuit board, if it was removed, and fasten it using
the respective screw.
Care should be taken when
using the screw driver in order to avoid any
damage.
After that
the connections with
an
external contact
can be made, if necessary.
INTERNAL LAYOUT AND SETTINGS
INTERNAL LAYOUT AND SETTINGS
The device can be connected
with external contacts, via the KL1 terminal
Photo 1
Photo 2
9214