Certification 

The panels 

BS-1

632, BS-1634

 

and

 BS-1

636 are certified from HEEQAC. Also HEEQAC controls 

the production under CPR number: 

08

48

-CP

R

-

002

-1

 for the panel 

BS-1

632, 

08

48

-CP

R

-

003

-1

 for 

the panel 

BS-1

634  and 

08

48

-CP

R

-

004

-1

 for the panel 

BS-1

636. 

Below are  the markings:

Page 

10

 from 

10

921163600_09_022

WARRANTY

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is 
specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each 
product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official 
documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-
setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. 

Products that have 

been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty 
period is valid.

 Olympia Electronics reserves the right to repair or to replace the returned goods and to or not

 

charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the 
buyer the transportation cost.

HEAD OFFICE

72nd km. O.N.R. Thessaloniki-Katerini

P

.

C

. 60

300

 

P.O. Box 06 Eginio Pierias

 

Greece

www.olympia-electronics.gr
[email protected]

CONVENTIONAL 6-ZONE
FIRE ALARM PANEL
INSTALL IN ACCORDANCE WITH
PRODUCT MANUAL: 
921163600_08_021 (GREEK)

921163600_09_0

2

2 (ENGLISH)

POWER SUPPLY:
220-240V AC/50-60Hz

EN 54-2:1997 +A1:2006
EN 54-4:1997 +A1:2002 +A2:2006
0848-CPR-004

-1

DoP No: 921163600_59_004
Provided option:
Output to fire alarm device(s),

delays to outputs
DISCONNECT POWER BEFORE
SERVICING 
Production 
Date:

/           /     

BS-1636

14

0848

72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Eginio Pierias Greece

CONVENTIONAL 4-ZONE
FIRE ALARM PANEL
INSTALL IN ACCORDANCE WITH
PRODUCT MANUAL: 
921163600_08_0

2

1 (GREEK)

921163600_09_0

2

2 (ENGLISH)

POWER SUPPLY:
220-240V AC/50-60Hz

EN 54-2:1997 +A1:2006
EN 54-4:1997 +A1:2002 +A2:2006
0848-CPR-003

-1

DoP No: 921163400_59_004
Provided option:
Output to fire alarm device(s),
delays to outputs
DISCONNECT POWER BEFORE
SERVICING 
Production 
Date:

/           /     

14

0848

BS-1634

72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Eginio Pierias Greece

CONVENTIONAL 2-ZONE
FIRE ALARM PANEL
INSTALL IN ACCORDANCE WITH
PRODUCT MANUAL: 
921163600_08_0

2

1 (GREEK)

921163600_09_0

2

2 (ENGLISH)

POWER SUPPLY:
220-240V AC/50-60Hz

EN 54-2:1997 +A1:2006
EN 54-4:1997 +A1:2002 +A2:2006
0848-CPR-002-1
DoP No: 921163200_59_004
Provided option:
Output to fire alarm device(s),
delays to outputs
DISCONNECT POWER BEFORE
SERVICING 
Production 
Date:

/           /     

14

0848

BS-1632

72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Eginio Pierias Greece

Summary of Contents for BS-1632

Page 1: ...12V 2 6Ah All functions and indications are according to European Norms EN 54 2 and EN 54 4 Top cover retaining screws Control Keyboard and indication leds Mounting holes Battery compartment two 920 M...

Page 2: ...respond to the siren outputs If a siren out has a short circuit or open circuit then the corresponding LED will blink If a siren is disabled the corresponding LED will light The next group of indicato...

Page 3: ...iren 1 and Siren2 LED lights for the siren 2 Using the keys 1 and 2 we can enable or disable the respective sirens The disabled sirens have a LED lighted The panel exits this mode if no key is pressed...

Page 4: ...nd corresponding functions 921163600_09_022 Fault zone 1 Alarm zone 2 Alarm zone 1 Without Delay 30 second Delay 60 second Delay 90 Second Delay LED ON LED OFF LED OFF LED OFF LED OFF LED OFF LED ON L...

Page 5: ...res with a cross section cable of 1 5mm Page 5 from 10 Figure 2 Connecting 4 detector bases to zone 1 Each base can accept BS 655 BS 660 or BS 657 detectors A remote indication LED BS 572 is connected...

Page 6: ...larm condition ATTENTION The relays are rated at 30VDC and 5A maximum No 230VAC signals can be connected to these relays Siren Sounder Connections Each panel offers 2 independent circuits for connecti...

Page 7: ...sed is 2 5mm Connecting the mains power supply 220 240V AC The panel has holes on the back side for all the wiring to pass through You can connect cables with max conductor diametre of 2 5mm to the pa...

Page 8: ...r is deactivated and the LED is turned off When a siren output has an open circuit then the internal buzzer is activated and the corresponding fault LED lights If the problem is corrected then the buz...

Page 9: ...rrents outside limits be connected All relays output must be protected with a fuse of the same rating Outputs Relays 325 x 240 x 85 mm 54 2 54 4 2 years Dimensions Weight Produced in accordance to Gua...

Page 10: ...erini P C 60300 P O Box 06 Eginio Pierias Greece www olympia electronics gr info olympia electronics gr CONVENTIONAL 6 ZONE FIRE ALARM PANEL INSTALL IN ACCORDANCE WITH PRODUCT MANUAL 921163600_08_021...

Reviews: