1
2
Care and maintenance
••••
Olsberg electric convector units do not require any
specific maintenance.
••••
If the unit is operating in places where there is an
excess of dust, you are recommended to clean the
air inlet and outlet grilles from time to time, using a
vacuum-cleaner nozzle attachment to remove any
dust deposits.
••••
DO NOT use abrasive cleaning products to remove
dirt from the outer surfaces of the unit. Use a mild
household detergent or just a soft, damp cloth.
••••
Note that the unit’s connection lead is a special
part. If the lead becomes damaged, it MUST be
replaced with the appropriate original component.
Technical specifications
- Temperature-setting range ........approx. 5°C to 35°C
-
Temperature-reduction phase ...ca. 3.5K
-
Voltage.......................................
1
/N ~ 230V
-
Protection rating II
................double insulated
-
Protection class ....................splash-proof
Type
Power
(watt)
Dimensions
HxWxD
1)
(mm)
Weight
(approx. kg)
Room-temperature
regulation
1
5/
1
92-3 500 440x340x80 3.7
electronic
1
5/
1
93-3 750 440x340x80 3.7
electronic
1
5/
1
94-3
1
000 440x420x80 4.3
electronic
1
5/
1
95-3
1
250 440x500x80 4.8
electronic
1
5/
1
96-3
1
500 440x580x80 5.6
electronic
1
5/
1
97-3
1
750 440x660x80 6.
1
electronic
1
5/
1
98-3 2000 440x740x80 6.7
electronic
1
5/
1
99-3 2500 440x900x80 7.9
electronic
1
)
Dimension D does not include control housing or wall-fixing bracket
Depth of wall-fixing bracket: 22mm
Note:
The identification plate is located inside the device, behind the air outlet grille.
When ordering spares, please be sure to indicate the type
and
serial number.
Summary of Contents for Corona Series
Page 1: ...Anleitung Manual Instruction Corona...
Page 14: ...14 N POCC DE ME03 B06068 15 15 15 16 17 17 18 18 19 o F RUS...
Page 15: ...15 10 10 15 50 22...
Page 17: ...17 3 5 5 C 35 C 2 3 1 0 1 3 5 2 1 2 3 4 5 6 7 8 9 3 4 4 F 4 4 M...
Page 19: ...19...
Page 26: ...26...
Page 27: ...27...