Summary of Contents for AirCom Zentral

Page 1: ...OLSBERG Instruction Manual OLSBERG AirCom Zentral Heating and ventilation system...

Page 2: ...earances 28 On site preparation for installation 28 Flow and return pipework 28 External air ducting 29 Earthed plug and socket 29 Dimension diagrams 29 31 Assembly 32 34 Electrical connection 35 Circ...

Page 3: ...d due to high air humidity and false ventilation can be prevented Steam and smells from bathroom and kitchen extracted Energy savings You will save heating costs as up to 70 of the heat from the extra...

Page 4: ...ed in the cross flow heat exchanger by the ex hausted air Following this the pre heated air is drawn across a radiator The air is then heated up to room temperature level and is then passed through th...

Page 5: ...e en tirely of recyclable materials The packaging and appliance parts have been marked according to present requirements and or possibilities to allow the best possible disposal or re cycling at a fut...

Page 6: ...e position The ventilation appliance is designed to be mounted on an external wall as the fresh air and exhaust air ducting must be run to the outside Preferably a posi tion under a window should be c...

Page 7: ...behind out of the wall or from below out of the floor for this type of connection If the heating pipes come sideways out of the wall the radiator is to be converted to a right hand connection to the...

Page 8: ...ositions Fig 3 The left hand duct is always for the fresh air inlet and the right hand duct is always for the exhaust air outlet The knock outs in the wall mounting strip are larger than the external...

Page 9: ...st air Floor Template accessory X Dimension of radiator connector angle fitting from middle of heating pipework to lower edge of radiator fittings Fresh air Exhaust air X Dimension of radiator connect...

Page 10: ...figuration Air ducts Radiator connectors Heating pipes Connection from side Fig 6 Location of earthed socket Fresh air Exhaust air Floor Floor Lower edge of appliance inside thread Type Fresh air Exha...

Page 11: ...able compen satory material must be placed at the fixing lo cations In the area of the air ducts PU foam or silicon must be used to provide a seal between the mounting strip and the wall Plugs and scr...

Page 12: ...ng buildings OLSBERG offers suitable connect ing pipe sets as an accessory This pipework set makes the connection at the rear of the appliance to the connections on the right hand side of the applianc...

Page 13: ...the appliance clearance to left side inner panel approx 15mm to right side panel of appliance approx 20mm Fix the screws at the top right and left of the fixing bracket firmly Connect the radiator fir...

Page 14: ...ith a cable binder Only plug the device plug into the protected earthed socket when all mounting tasks have been concluded Circuit diagram 2 78 4536 0112 OFF Fan speed switch Electronics Printed Circu...

Page 15: ...ing label for type 36 011 2 Spare parts By any queries concerning spare parts it is necessary to quote the type number and the fabrication number printed on the rating label We recommend that you note...

Page 16: ...strip which is separately packed serves as a marker for the position of the air ducts during the construction phase Note The wall mounting strip is absolutely neces sary for fixing the appliance It c...

Page 17: ...itch being over twisted Appliances that are not designed in according to the German Energy Saving Regula tions can have this screw removed so that the op erating mode Fresh Air summer operation in or...

Page 18: ...etting 2 3 for continuous opera tion dependent on the size of the room If increased ventilation is necessary the fan speed should be tem porarily increased This naturally also increases the noise of o...

Page 19: ...ectrical parts when the sealing panel is removed The ventilation module parts are to be removed in the following order 1 Remove the fresh air filter 1 2 Remove the cross flow heat exchanger 2 Make sur...

Page 20: ...densate indicator tube and pull it forwards out of the appliance Then hold the end of the tube down below the level of the sump so that the condensate can drain off into another vessel Cleaning the ex...

Page 21: ...be carried out by a competent electri cian Trouble shooting If the AirCom Zentral should not work for any reason please first check the following procedures Is the appliance plugged in Are the circui...

Page 22: ...ir flow volume 20 60 m h Fan rating 8 38 W Sound pressure level 26 48 dB A Heat recuperation from exhaust air up to 70 Radiator heating rating at 70 55 C at 55 45 C 1005 W 633 W 1340 W 844 W 1675 W 10...

Page 23: ...88 6 78 4636 0112 05 2011 Olsberg GmbH H ttenstra e 38 59939 Olsberg T 49 2962 805 0 F 49 2962 805 180 info olsberg com olsberg com...