Olorin VC190D User Manual Download Page 5

5

Product Features

Standard delivery

The product is normally delivered in 2 main parts, which, when mounted together, form a normal 

monitor for desktop use. 

• a LCD panel with TFT picture element which also contains the lamps for the backlight along  

  with necessary electronics and cable connectors as well as power connector. These parts are  

  mounted inside a plastic housing. 

• a base unit (stand) to be mounted at the VESA holes at the back of the panel.  

For certain applications, when the monitor is to be placed on a wall or built into a desk, then only 

the LCD panel part is delivered. In these cases it is quite often delivered with the plastic housing 

removed in what is called “open frame”. Certain other options or special mounting components 

might have been pre-installed.

When the monitor has been delivered as open frame there is a greater risk to come 

in contact with electric parts which could cause harm to yourself or your property. It 

should therefore only be handled with special precaution and only by properly trained 

service personnel.

Power management

This unit has power management system. The monitor will go into “sleep mode”, where power 

consumption is less than 5W, whenever either horizontal or vertical signals or both disappear. 

High performance panel element

The color LCD panel used in this product is specifically designed for advanced applications such 

as viewing digital X-ray images. ALS (Automatic Luminance Stabilization) circuits gives a stable 

picture for the life of the product. ALC (Automatic Luminance Control) circuits will automatically 

adjust for the decay of the backlight lamps.

Front sensor for calibration and quality assurance

The monitor is equipped with a front sensor used for stabilizing the calibrated luminance. It is also 

used for un-attended calibration and quality checks. The monitor is bundled with PerfectLum™ 

calibration and quality assurance software.

Preloaded DICOM curve

The monitor has a preloaded Barten DICOM curve for use as a plug-n-play X-ray review display.

Ergonomic features

To ease eyestrain on the user, the panel features excellent viewing angles. In addition, the base 

unit can be adjusted to fit the individual user’s need by adjusting the height and tilt of the monitor.

VESA® standard wall / arm mountings

The unit is compliant with VESA’s 100mm-pitch (75 mm for 12” and 15” monitors) for hanging 

tools. The base unit is detachable; the panel can be mounted on a wall or arm according to user’s 

enviroment.

Warning

Summary of Contents for VC190D

Page 1: ...Display User s Manual VistaLine MedicLine VC190D MC190D MC200D www olorin com...

Page 2: ...2...

Page 3: ...ct 13 12 Disposal of the Product 13 13 Getting started 14 14 How to assemble Panel and Base unit 15 15 Mounting on a wall or LCD arm 16 16 Rotating the LCD Panel 17 17 Connection Method 18 18 Input si...

Page 4: ...duct or to other attached devices appliances Throughout this manual the following symbols are used to guide you to the proper use of the product Keep this Users Manual in an easy accessible and safe p...

Page 5: ...de where power consumption is less than 5W whenever either horizontal or vertical signals or both disappear High performance panel element The color LCD panel used in this product is specifically desi...

Page 6: ...k of electrical shock which could cause bodily harm possibly even death Most certainly such electrical shock will damage the product The product can also be delivered with certain options installed Su...

Page 7: ...e or in an inclined place which might cause injuries if it falls down Do not place the unit where it is subject to direct sunlight or near any heating device This could cause overheating resulting in...

Page 8: ...ly turn off the power and disconnect the plug from the outlet Continuing to use the unit under such condition may lead to electric shock and or fire For assistance contact your local re seller In the...

Page 9: ...ent and inspection Do not remodel or repair It may lead to fire electric shock or injuries Clean the dust inside the display once a year The dust that accumulates inside the unit may lead to fire Ask...

Page 10: ...n Union member states RoHS for use within the European Union member states Tests and Approvals for MedicLine Series Each product in the MedicLine series has additionally been tested for risk of electr...

Page 11: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re...

Page 12: ...y improper use of the product by the user or any use under other abnormal circumstances the use or inability to use this product the use for other purposes than the intended use as described in this d...

Page 13: ...cleaning the cabinet do NOT use thinner benzene or alcohol as these might damage the plastic and cause the paint to peel off Do NOT use organic solvent such as acetone and toluene when cleaning the p...

Page 14: ...y Standard Items The LCD monitor panel User s manual Warranty booklet AC DC adapter AC Power cord DVI to DVI cable Optional Items The Base unit with 4 Screws and Screwdriver CD ROM with PerfectLum sof...

Page 15: ...ced so that the OSD wheel is at the lower left corner seen from yourself Place the metal plate onto the VESA mounting cut out on the back of the panel Hold the bottom of the base unit towards yourself...

Page 16: ...we strongly recommend that you use wall mount kits with attached M4 10mm screws and which can hold a load of more than the weight of the monitor Ensure it is securely and safely installed If you mount...

Page 17: ...90 degrees Procedure 1 Tilt the LCD panel upward Perform this procedure before sliding the panel upward 2 Lift the LCD panel to the top 3 Rotate the LCD panel by 90 degrees 4 Reposition the LCD panel...

Page 18: ...h input connectors there are available on your monitor and which cable you should connect depends on your source for the input signal VGA DVI HDMI or Displayport output from a PC If your source is VGA...

Page 19: ...19 Input signals Connections 19 and 20...

Page 20: ...ust the monitor Rotate Downward Move Up Right Increase Larger More Rotate Upward Move Down Left Decrease Smaller Less Button Press Execute Do Save 3 Change of Brightness Setting If you rotate the Cont...

Page 21: ...pending on the control you selected a submenu of the control with a status bar will appear The status bar indicates in which direction from the factory preset your adjustments are being made Rotate th...

Page 22: ...separate sub menu you can set individual values for Red Green and Blue Clear base Barten A special color mode intended for viewing of X ray pictures Has a preset grayscale curve in accordance with the...

Page 23: ...put it supports Sync on green and the interlace timing can be displayed Recall If you execute Recall the monitor will be reset to values that are default values at time of delivery Lum stable Automati...

Page 24: ...ory for calibrations and quality assurance tests The history is visualized in graphs and can be exported to printable reports The software has a backup function that makes sure everything can be store...

Page 25: ...timing Pseudo display timing Display mode Resolution Frequency 19 20 Horizontal Vertical Horizontal kHz Vertical Hz VGA 720 400 31 5 70 640 480 31 5 60 VESA 640 480 37 9 72 640 480 37 5 75 800 600 35...

Page 26: ...GA DVI I DDC DDC 2B DDC CI for calibration Power Power supply External 12V Power consumption Max 50W 5W in stand by Functionality Automatic adjustment Yes via OSD OSD for settings Yes Speakers No Lumi...

Page 27: ...color Graphite grey standard or white optional Base unit Height adjustable Yes Tilting and swivel Yes Mounting Kensington lock Yes prepared VESA standard Yes 100 mm 431 239 64 353 467 Please note that...

Page 28: ...Connections VGA DVI I DDC DDC 2B DDC CI for calibration Power Power supply External 12V Power consumption 60W 5W in stand by Functionality Automatic adjustment Yes via OSD OSD for settings Yes Speaker...

Page 29: ...r Graphite grey standard or white optional Base unit Height adjustable Yes Tilting and swivel Yes Mounting Kensington lock Yes prepared VESA standard Yes 100 mm 473 241 76 377 476 Please note that val...

Page 30: ...ite it could come down to 5000K Typical values In product specifications there are values for brightness contrast view angles etc The values are given as typical values meaning that actual value for a...

Page 31: ...en saver that moves around on the screen so that no static image is constantly shown Slow operating in cold environments The thin film transistors contain some liquid that will cause them to operate s...

Page 32: ...of seconds PLEASE NOTE THAT A SCREENSAVER WILL NOT SWITCH OFF THE BACKLIGHT LAMPS AND THUS IS NOT A SOLUTION FOR LONGER LIFE The higher the luminance is set on the monitor the greater is the wear of...

Page 33: ...light If not the adapter might be broken If you have another adapter of the same type you can verify by using that adapter If yes there is a problem with the panel which should be repaired If yes then...

Page 34: ...The video cable must be connected for reading of the information to take place 1 DDC Display Data channel and 2 VESA are registered trademarks of Video Electronics Standards Association DICOM Digital...

Page 35: ...35 Contact Olorin AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 Fax 46 0 300 566 789 E mail info olorin com www olorin com OLM0001EN_1204...

Reviews: