Olorin MedicLine Series User Manual Download Page 34

34

Specifications

VL221D

Display

Screen size, Format

21.5” 16:9

Brightness, candela/m2

250 cd/m2

Contrast

1000:1

Resolution, Megapixel

1920x1080, 2.1 MP

Response time

14 ms

Viewing angles, H/V

178/178

Color depth

16.7M

Panel type

N/A

Backlight type

LED

Environmental

Operating

Storage

Temperature, Celcius

10 to 40 C

-20 to 60 C

Humidity (non-

condensation)

30 to 75 % RH

10 to 90 % RH

Air pressure

700~1060hPa

500~1060hPa

Input signal

Connections

(1) DVI-I (29-pin) connector:Compliant with DVI 1.0 

(2) S-video connector: Color signal:0.286Vp-p/75 Ω 

Brightness signal:1Vp-p/75 Ω

 

(3) BNC connector: Composite signal:1Vp-p/75 Ω

 

(4) Audio signal (pin jack3.5mm) connector:0.2-2.0 Vrms 

(5) RJ 45 connector: Extended interface (OSD control)

Power

Power supply

12V External power supply

Power consumption

Approx. 40W Max. / < 2W in stand-by

Functionality

Automatic adjustment

Yes, via OSD.

OSD for settings

Yes

Speakers

Yes

Luminance 

compensation

ALC

Pivot

Yes, graphics card dependent.

Protective glass

Yes, true flat. IP65

Touch panel

Optional, PCAP Touch panel IP65

Dimming

Optional

Sunlight Readable

Optional

DICOM pt. 14 preset

N/A

International 

standards

Medical certificates

N/A

IT certificates

CE(EN 60950-1, EN55024)

Warranty

Replacement warranty

Two (2) years

 

Summary of Contents for MedicLine Series

Page 1: ...www olorin com Display User s Manual VistaLine MedicLine MLD198 VLD158 VLD178 VLD198 VL127D VL221D VL227D VL241D VL247D...

Page 2: ...2...

Page 3: ...osal of the Product 13 12 Getting started 14 13 How to assemble Panel and Base unit 15 14 Mounting on a wall or LCD arm 16 15 Rotating the LCD Panel 17 16 Connection Method 18 17 Input signals 19 18 H...

Page 4: ...duct or to other attached devices appliances Throughout this manual the following symbols are used to guide you to the proper use of the product Keep this Users Manual in an easy accessible and safe p...

Page 5: ...nly by properly trained service personnel Power management This unit has power management system The monitor will go into sleep mode where power consumption is less than 5W whenever either horizontal...

Page 6: ...k of electrical shock which could cause bodily harm possibly even death Most certainly such electrical shock will damage the product The product can also be delivered with certain options installed Su...

Page 7: ...e or in an inclined place which might cause injuries if it falls down Do not place the unit where it is subject to direct sunlight or near any heating device This could cause overheating resulting in...

Page 8: ...ly turn off the power and disconnect the plug from the outlet Continuing to use the unit under such condition may lead to electric shock and or fire For assistance contact your local re seller In the...

Page 9: ...ent and inspection Do not remodel or repair It may lead to fire electric shock or injuries Clean the dust inside the display once a year The dust that accumulates inside the unit may lead to fire Ask...

Page 10: ...within the European Union member states RoHS for use within the European Union member states Tests and Approvals for MedicLine Series Products in the MedicLine series are generally tested to comply wi...

Page 11: ...nclosure and therefore are not accessible The accessible parts of the enclosure and output are DOUBLE INSULATED from all mains voltage electrical parts Ground continuality test is not relevant Leakage...

Page 12: ...or negligently improper use of the product by the user or any use under other abnormal circumstances the use or inability to use this product the use for other purposes than the intended use as descr...

Page 13: ...cleaning the cabinet do NOT use thinner benzene or alcohol as these might damage the plastic and cause the paint to peel off Do NOT use organic solvent such as acetone and toluene when cleaning the p...

Page 14: ...s manual AC DC adapter AC Power cord DVI to DVI cable DVI to VGA cable 3 5 mm Audio cable Optional Items Base unit with 4 Screws and Screwdriver S video cable DVI to VGA DVI splitter cable Optional It...

Page 15: ...ced so that the OSD wheel is at the lower left corner seen from yourself Place the metal plate onto the VESA mounting cut out on the back of the panel Hold the bottom of the base unit towards yourself...

Page 16: ...we strongly recommend that you use wall mount kits with attached M4 10mm screws and which can hold a load of more than the weight of the monitor Ensure it is securely and safely installed If you mount...

Page 17: ...t by 90 degrees Procedure 1 Tilt the LCD panel upward Perform this procedure before sliding the panel upward 2 Lift the LCD panel to the top 3 Rotate the LCD panel by 90 degrees 4 Reposition the LCD p...

Page 18: ...l VGA DVI HDMI or Displayport output from a PC If your source is VGA analog then use either a VGA to VGA cable for connection to the VGA connector or a VGA to DVI I cable for connection to the DVI I c...

Page 19: ...Input signals 15 17 and 22 1 19 Connections RJ45 connector placed at bottom of panel DVI I to DVI D VGA splitter cable 1 On 22 monitors RJ45 is located on the opposite side of the backet next to Audi...

Page 20: ...Up Right Increase Larger More Rotate Upward Move Down Left Decrease Smaller Less Button Press Execute Do Save In the SOURCE menu clicking navigates the menu letting it idle confirms 2 Change of Bright...

Page 21: ...ontrol Dial inward to select that control or to activate that function Depending on the control you selected a submenu of the control with a status bar will appear The status bar indicates in which di...

Page 22: ...color mode has been selected Display 1 H Position Adjust horizontal screen position V Position Adjust vertical screen position Hue 2 Adjust the hue of the color settings Color mode Cool Select a cold...

Page 23: ...monitor or not Active only for when you adjust the brightness by turning the control wheel without having entered the OSD menu You select YES or NO if it should be shown or not ALC Automatic Luminanc...

Page 24: ...ich can be measured When a conductive object such as a finger comes into contact with a PCAP panel it distorts the local electrostatic field at that point This is measurable as a change in capacitance...

Page 25: ...480 60 Hz O O O O O 640 x 480 72 Hz O O O O O 640 x 480 75 Hz O O O O O 800 x 600 56 Hz O O O O O 800 x 600 60 Hz O O O O O 800 x 600 70 Hz O O O O O 800 x 600 72 Hz O O O O O 800 x 600 75 Hz O O O O...

Page 26: ...al 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface OSD control Power Power su...

Page 27: ...nal Mounting Kensington lock Yes VESA standard 75 x 75 mm 100 x 100 mm OLORIN AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 Fax 46 0 300 566 789 info olorin com Shown here with...

Page 28: ...S video connector Color signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interfac...

Page 29: ...Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm OLORIN AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 Fax 46 0 300 566 789 info olor Shown here with optional ba...

Page 30: ...l 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface OSD control Power Power sup...

Page 31: ...Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm OLORIN AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 Fax 46 0 300 566 789 info olorin com Shown here with option...

Page 32: ...h DVI 1 0 2 S video connector Color signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Exten...

Page 33: ...33 Specifications VL127D Appearance Net weight 1 6 Kgs Measurements WxHxD 262 5 x 222 6 x 45 8 mm Product color Open frame gray Open frame Yes Mounting Kensington lock N A VESA standard 75 x 75 mm...

Page 34: ...signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface OSD control Power Powe...

Page 35: ...HxD 537 37 x 328 87 x 59 mm Product color Graphite grey Open frame Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm Shown here with optional base unit Weight and measurements might dif...

Page 36: ...video connector Color signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface...

Page 37: ...VL227D Appearance Net weight 5 0 kgs Measurements WxHxD 537 37 x 328 87 x 65 mm Product color Graphite grey Open frame Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm Shown here with...

Page 38: ...nnector Color signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface OSD cont...

Page 39: ...xD 582 07 x 350 07 x 62 5 mm Product color Graphite grey Open frame Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm Olorin VL241D http www olorin com Weight and measurements might dif...

Page 40: ...video connector Color signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface...

Page 41: ...ications VL247D Appearance Net weight 6 4 kg Measurements WxHxD 582 07 x 350 07 x 65 7 mm Product color Graphite grey Open frame Mounting Kensington lock Yes VESA standard 100 x 100 mm in VL247D www o...

Page 42: ...or signal 0 286Vp p 75 Brightness signal 1Vp p 75 3 BNC connector Composite signal 1Vp p 75 4 Audio signal pin jack3 5mm connector 0 2 2 0 Vrms 5 RJ 45 connector Extended interface OSD control Power P...

Page 43: ...r Graphite grey Open frame Optional Mounting Kensington lock Yes VESA standard 100 x 100 mm OLORIN AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 Fa Shown here with optional base...

Page 44: ...ite it could come down to 5000K Typical values In product specifications there are values for brightness contrast view angles etc The values are given as typical values meaning that actual value for a...

Page 45: ...en saver that moves around on the screen so that no static image is constantly shown Slow operating in cold environments The thin film transistors contain some liquid that will cause them to operate s...

Page 46: ...uple of seconds PLEASE NOTE THAT A SCREENSAVER WILL NOT SWITCH OFF THE BACKLIGHT LAMPS AND THUS IS NOT A SOLUTION FOR LONGER LIFE The higher the luminance is set on the monitor the greater is the wear...

Page 47: ...light If not the adapter might be broken If you have another adapter of the same type you can verify by using that adapter If yes there is a problem with the panel which should be repaired If yes then...

Page 48: ...The video cable must be connected for reading of the information to take place 1 DDC Display Data channel and 2 VESA are registered trademarks of Video Electronics Standards Association DICOM Digital...

Page 49: ...49 Olorin AB Marios gata 11 SE 434 37 Kungsbacka Sweden Phone 46 0 300 566 780 E mail info olorin com www olorin com Contact OLM0002EN_1908...