2MH/2MJ/2MK/2ML
1-5-43
(3) Detaching and refitting the high voltage PWB
Procedure
1. Remove the developer unit (See page
1-5-27).
2. Remove the drum unit (See page 1-5-
3. Remove the cassette (See page 1-5-6).
4. Remove the left cover and right cover
(See page 1-5-3).
5. Remove the power source PWB (See
page 1-5-40).
6. Turn the machine with the front side up.
7. Remove the stopper.
8. Remove the DU holder.
Figure 1-5-64
9. Pull the DU bush out.
10. Remove the DU cover assembly.
Figure 1-5-65
DU holder
Stopper
DU bush
DU cover
assembly
Y113860-1
Sevice Manual