2MH/2MJ/2MK/2ML
1-4-19
1-4-4 Electric problems
Problem
Causes
Check procedures/corrective measures
(1)The machine
does not operate
when the power
switch is turned on.
1. No electricity at the
power outlet.
Measure the input voltage.
2. The power cord is
not plugged in prop-
erly.
Check the contact between the power plug and the outlet.
3. The top cover is not
closed completely.
Check the top cover.
4. Broken power cord.
Check for continuity. If none, replace the cord.
5. Defective power
switch.
Check for continuity across the contacts. If none, replace
the power source PWB (See page 1-5-40).
6. Blown fuse in the
power source PWB.
Check for continuity. If none, remove the cause of blowing
and replace the power source PWB (See page 1-5-40).
7. Defective interlock
switch.
Check for continuity across the contacts of interlock switch.
If none, replace the power source PWB (See page 1-5-40).
8. Defective power
source PWB.
Replace the power source PWB (See page 1-5-40).
9. Defective control
PWB.
Replace the control PWB (See page 1-5-37).
(2)Right cooling
fan motor does not
operate.
1. Broken right cooling
fan motor coil.
Check for continuity across the coil. If none, replace the
right cooling fan motor.
2. Defective harness
between right cooling
fan motor and control
PWB (YC27), or
improper connector
insertion.
Reinsert the connector. Also check for continuity within the
connector harness. If none, remedy or replace the harness.
3. Defective control
PWB.
Replace the control PWB (See page 1-5-37).
(3)Left cooling fan
motor does not
operate.
1. Broken left cooling
fan motor coil.
Check for continuity across the coil. If none, replace the left
cooling fan motor.
2. Defective harness
between left cooling
fan motor and control
PWB (YC104), or
improper connector
insertion.
Reinsert the connector. Also check for continuity within the
connector harness. If none, remedy or replace the harness.
3. Defective control
PWB.
Replace the control PWB (See page 1-5-37).
Y113860-1
Sevice Manual
Summary of Contents for d-Copia 3003MF
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 25: ...2MH 2MJ 2MK 2ML 1 1 11 This page is intentionally left blank Y113860 1 Sevice Manual...
Page 97: ...2MH 2MJ 2MK 2ML 1 3 66 This page is intentionally left blank Service Manual Y113860 1...
Page 137: ...2MH 2MJ 2MK 2ML 1 4 40 This page is intentionally left blank Service Manual Y113860 1...
Page 219: ...2MH 2MJ 2MK 2ML 2 1 24 This page is intentionally left blank Service Manual Y113860 1...
Page 225: ...2MH 2MJ 2MK 2ML 2 2 6 This page is intentionally left blank Service Manual Y113860 1...
Page 254: ...INSTALLATION GUIDE INSTALLATION GUIDE FOR PAPER FEEDER...
Page 257: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2012 1ST EDITION 257 Y113860 1...